Mã lỗi Roland MDX540 — Trang 2/4
Code:
Tất cả lỗi (32)
FE:10
FE:11
FE:12
FE:13
FE:14
FE:15
FE:16
FE:17
FE:18
FE:19
FE:2
FE:20
FE:21
FE:23
FE:3
FE:4
FE:5
FE:6
FE:7
FE:8
FE:9
IS:10
IS:2
IS:6
XY:1
XY:14
XY:16
XY:5
ZA:1
ZA:14
ZA:16
ZA:5
Description: ATC fails to release the tool.
Causes: ATC fails to release the tool. Tool Hold Sensor is not operating correctly.
Description: Rear Magazine Cover Sensor doesn't become the expected state in the initial operation.
Causes: Rear Magazine Cover Sensor is not operating properly. The motor for the Magazine Cover is not operating properly.
Description: There is a communication problem between the Main CPU and XY Servo CPU.
Causes: There is a problem in the electric route between the Main CPU and the XY Servo CPU. XY Servo CPU is not operating correctly.
Description: Rear Magazine Cover Sensor doesn't become the expected state when opening the Magazine Cover.
Causes: Rear Magazine Cover Sensor is not fixed correctly or broken. The stepping motor for the Magazine Cover is not operating properly.
Description: Front Magazine Cover Sensor doesn't become the expected state when closing the Magazine Cover.
Causes: Front Magazine Cover Sensor is not fixed correctly or broken. The stepping motor for the Magazine Cover is not operating properly.
Description: Panel CPU is not operating correctly.
Causes: The program for the Panel CPU fails to be downloaded from the Main CPU in the initial operation. Panel Junction board is defective. There is a bad contact or a cut-line in the cable.
Description: XY Servo CPU on the Main board is not operating correctly.
Causes: The program for the XY Servo CPU fails to be downloaded from the Main CPU in the initial operation.
Description: There is a communication problem between the Main CPU and ZA Servo CPU.
Causes: There is a problem in the electric route between the Main CPU and the ZA Servo CPU. ZA Servo CPU is not operating correctly.