Mã lỗi Roland MDX540 — Trang 3/4
Description: ZA Servo CPU on the Main board is not operating correctly.
Causes: The program for the ZA Servo CPU fails to be downloaded from the Main CPU in the initial operation.
Description: There is a communication problem between the Main CPU and Spindle Servo CPU.
Causes: There is a problem in the electric route between the Main CPU and the Spindle Servo CPU. Spindle Servo CPU is not operating correctly.
Description: Spindle Servo CPU on the Main board is not operating correctly.
Causes: The program for the Spindle Servo CPU fails to be downloaded from the Main CPU in the initial operation.
Description: X Limit SW can not be detected.
Causes: X Limit SW is not attached correctly or defective. There is a bad contact or a cut-line in the cable.
Description: Y Limit SW can not be detected.
Causes: Y Limit SW is not attached correctly or defective. There is a bad contact or a cut-line in the cable.
Description: There is a problem in the spindle control circuit.
Causes: There is a problem in the spindle control circuit or the electric route between the Main board and Spindle board.
Description: Power voltage of the Spindle Motor is 20V or less.
Causes: Spindle Motor is defective. There is a bad contact or a cut-line in the cable. Spindle Board is defective
Description: There is a problem in the Spindle motor.
Causes: Spindle Motor is defective There is a bad contact or a cut-line in the cable.