Code: 0102

Description: Even though the machine carries out the regular movement, the output of Head Lock Sensor does not reach the expected value.
Causes: Head Lock Sensor does not work correctly or is broken.

Code: 0103

Description: Even though the machine carries out the regular movement, the output of Limit Sensor does not reach the expected value.
Causes: Limit Sensor does not work correctly or is broken.

Code: 0104

Description: Even though the machine carries out the regular movement, the output of Capping Sensor does not reach the expected value.
Causes: Capping Motor does not work correctly or is broken. Capping Unit does not work correctly or is broken. Capping Sensor does not work correctly or is broken. Wiring or Flexible Cable has short circuited or cut-line.

Code: 0105

Description: Tool Carriage Connection Error
Causes: Fault of Tool Carriage Connection Loose of Connection Part Fault of the Limit Position Initialize value Limit Sensor does not work correctly or is broken.

Code: 0106

Description: Machine fails to disconnect the Tool Carriage from the Head Carriage.
Causes: Fault of Tool Carriage Connection Loose of Connection Part Fault of the Limit Position Initialize value Limit Sensor does not work correctly or is broken.

Code: 0107

Description: Linear Encoder Setup has not been done.
Causes: Linear Encoder Setup has not been done. Linear Encoder Setup is ended before it is completed.

Code: 0109

Description: Even though the machine carries out the regular movement, the output of the Wiper Sensor does not reach the expected value.
Causes: Wiper Motor error Defect of Wiper Unit Defect of Wiper Sensor Cut-line or short-circuit of cable and Flexible cable

Code: 0110

Description: Input value from Linear Encoder is not changed by the Linear Encoder origin setup. When Motor stops during printing, expected movement is not completed on some head.
Causes: Read error of Linear Encoder. Read error of Encoder on Scan Motor side. Belt is not fixed to Head Carriage firmly.