Description: 1. Seal tape is removed? 2. GND OPC is well grounded? 3. LSU running well? 4. Biss voltage is normal? 5. Lower toner?
Remedy: 1. Removing seal tipe 2. Measure the resistance between frame ground and the ground spring attached frame. Confirm stable ground. Unless bad ground, detach cabinet, check where is bad point 3.Adjust LSU or replace it 4. Normal Dev bias = -300V 5. Shake toner cartridge and print.If a liitke good, toner is empty
Description: 1. Check seal tape removing 2. LSU light power normal? 3. Enough toner? 4. High charger voltage? 5. Lower bias voltage 6. Contamination of high voltage contact 7. Transfer volatge and roller
Remedy: 1. Check and remove tape 2. LSU light power check is difficult. Compare with new one and check. 3. Check toner and developer counter 4-5. Measure all high voltage output 6. Leakage toner cause bad contact and increase contact resistance. Clean contaminated area.
Description: 1. Use recommended paper? 2. Check fusing temperature 3. The machine was under the low temperature for a long time?
Remedy: 1. Should use recommended paper 2. Check engine board. If you have not thermometer, measure the thermistor voltage to CPU, If 2.98V+-5% in printing CPU works well. Then, disassemble fuser and check the thermistor contact and thermistor. 3. Re-check after putting the machine in the warm place for certain period.