Description: The confirmation was requested for wired port, the server has rejected. / The confirmation protocol is not the same or user information (ID/Password) is wrong.
Remedy: Check the setting-up for 802.1x confirmation server. • Re-enter the server information and confirmation protocol. • Re-enter the user information.
Code: U1-2315
Display: Error #U1-2315 Turn off then on.
Description: The temperature control of fuser unit is abnormal.
Remedy: 1) Turn the machine off. Re-install the fuser unit. Then turn the machine on. Is the error message is disappeared? 2) If the problem persists, turn the machine off and remove the fuser unit. (Refer to 3.3.13) a) Check if the fuser connector is connected properly. b) Check if the input voltage is normal. c) Check if the thermistor is twisted or contaminated; and is in contact with the Heat Roller. 3) After confirming continuity in the fuser connector and the problem still exists; order an SMPS/HVPS and Fuser Unit and install as is necessary. • HVPS : JC44-00197A • SMPS : JC44-00095D (110V) / JC44-00096D (220V) • Fuser Unit : JC91-01023A (110V) / JC91-01024A (220V)
Code: U1-2320
Display: Error #U1-2320 Turn off then on.
Description: The temperature control of fuser unit is abnormal.
Remedy: 1) Turn the machine off. Re-install the fuser unit. Then turn the machine on. Is the error message is disappeared? 2) If the problem persists, turn the machine off and remove the fuser unit. (Refer to 3.3.13) a) Check if the fuser connector is connected properly. b) Check if the input voltage is normal. c) Check if the thermistor is twisted or contaminated; and is in contact with the Heat Roller. 3) After confirming continuity in the fuser connector and the problem still exists; order an SMPS/HVPS and Fuser Unit and install as is necessary. • HVPS : JC44-00197A • SMPS : JC44-00095D (110V) / JC44-00096D (220V) • Fuser Unit : JC91-01023A (110V) / JC91-01024A (220V)
Code: U1-2330
Display: Error #U1-2330 Turn off then on.
Description: The temperature control of fuser unit is abnormal.
Remedy: 1) Turn the machine off. Re-install the fuser unit. Then turn the machine on. Is the error message is disappeared? 2) If the problem persists, turn the machine off and remove the fuser unit. (Refer to 3.3.13) a) Check if the fuser connector is connected properly. b) Check if the input voltage is normal. c) Check if the thermistor is twisted or contaminated; and is in contact with the Heat Roller. 3) After confirming continuity in the fuser connector and the problem still exists; order an SMPS/HVPS and Fuser Unit and install as is necessary. • HVPS : JC44-00197A • SMPS : JC44-00095D (110V) / JC44-00096D (220V) • Fuser Unit : JC91-01023A (110V) / JC91-01024A (220V)
Code: U1-2334
Display: Error #U1-2334 Turn off then on.
Description: The temperature control of fuser unit is abnormal.
Remedy: 1) Turn the machine off. Re-install the fuser unit. Then turn the machine on. Is the error message is disappeared? 2) If the problem persists, turn the machine off and remove the fuser unit. (Refer to 3.3.13) a) Check if the fuser connector is connected properly. b) Check if the input voltage is normal. c) Check if the thermistor is twisted or contaminated; and is in contact with the Heat Roller. 3) After confirming continuity in the fuser connector and the problem still exists; order an SMPS/HVPS and Fuser Unit and install as is necessary. • HVPS : JC44-00197A • SMPS : JC44-00095D (110V) / JC44-00096D (220V) • Fuser Unit : JC91-01023A (110V) / JC91-01024A (220V)
Code: U1-2340
Display: Error #U1-2340 Turn off then on.
Description: The temperature control of fuser unit is abnormal.
Remedy: 1) Turn the machine off. Re-install the fuser unit. Then turn the machine on. Is the error message is disappeared? 2) If the problem persists, turn the machine off and remove the fuser unit. (Refer to 3.3.13) a) Check if the fuser connector is connected properly. b) Check if the input voltage is normal. c) Check if the thermistor is twisted or contaminated; and is in contact with the Heat Roller. 3) After confirming continuity in the fuser connector and the problem still exists; order an SMPS/HVPS and Fuser Unit and install as is necessary. • HVPS : JC44-00197A • SMPS : JC44-00095D (110V) / JC44-00096D (220V) • Fuser Unit : JC91-01023A (110V) / JC91-01024A (220V)
Code: U2-1112
Display: Error #U2-1111 Turn off then on.
Description: LSU Motor does not work normally.
Remedy: 1) Execute the LSU motor test in EDC mode. Check LSU motor operation sound. 2) If there is no sound, remove the right cover. Check if the LSU harness is connected on the main board properly. (picture-1) 3) If it is OK, remove the top cover. Check if the LSU harness is connected on LSU board properly. (picture- 2,3) 4) Check if the LSU harness is defective. (picture-4) 5) Reconnect the LSU harness and then execute the LSU motor test again. 6) If the problem persists, replace the LSU(JC97-04065A). 7) If the problem persists after replacing LSU, replace the main board.
Code: U2-1113
Display: Error #U2-1113 Turn off then on.
Description: LSU Motor does not work normally.
Remedy: 1) Execute the LSU motor test in EDC mode. Check LSU motor operation sound. 2) If there is no sound, remove the right cover. Check if the LSU harness is connected on the main board properly. (picture-1) 3) If it is OK, remove the top cover. Check if the LSU harness is connected on LSU board properly. (picture- 2,3) 4) Check if the LSU harness is defective. (picture-4) 5) Reconnect the LSU harness and then execute the LSU motor test again. 6) If the problem persists, replace the LSU(JC97-04065A). 7) If the problem persists after replacing LSU, replace the main board.