Description: Main motor lock. The main motor encoder pulse is not detected for 400msec.
Causes: Main motor defect Harness disconnection between the MCU PWB and the main motor. Control circuit failure
Remedy: Check the main motor operation with SIM 25-1. Check the harness and the connector between the MCU PWB and the main motor.
Code: L6 10
Description: Polygon motor lock. The lock signal (the specified rotation speed signal) is not supplied within the specified time (about 6 sec)after starting the polygon motor rotation.
Causes: LSU connector disconnection or harness disconnection in the LSU.
Remedy: Check the operation of the polygon motor with SIM 25-10. Check the harness and the connector connection. LSU replacement
Code: L8 01
Description: Zero cross pulse width is shifted by 55Hz ± 10% or more.
Causes: MCU PWB defect Power unit breakdown
Remedy: Check the harness and the connector. MCU PWB replacement Power unit replacement
Remedy: Check that the EEPROM is properly set. To prevent against loss of counter/adjustment values, record the values with simulation. U2 trouble cancel with SIM 16 MCU PWB replacement
Code: U2 11
Description: Counter check sum error. Counter check sum value stored in the EEPROM is abnormal.
Causes: EEPROM failure Control circuit hung up by noises MCU PWB EEPROM access circuit defect
Remedy: Check that the EEPROM is properly set. To prevent against loss of counter/adjustment values, record the values with simulation. U2 trouble cancel with SIM 16 MCU PWB replacement
Code: U2 12
Description: Adjustment value check sum error (EEPROM). Adjustment value data area check sum error
Causes: EEPROM failure Control circuit hung up by noises MCU PWB EEPROM access circuit failure
Remedy: Check that the EEPROM is properly set. To prevent against loss of counter/adjustment values, record the values with simulation. U2 trouble cancel with SIM 16 MCU PWB replacement
Code: U3 29
Description: Home position is not detected when starting mirror base shift.
Causes: Mirror unit defect Mirror home position sensor defect MCU PWB decfect Scanner wire disconnection
Remedy: Check the scanning operation with SIM 1-1.
Code: U9 00
Description: Communication trouble between MCU and OPE (OPE detection). Communication setup error, framing, parity, protocol error
Causes: Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
Remedy: Check the connectors and harness of the operation control PWB and the MCU PWB. Check grounding of the machine. Check the ROM of the operation control PWB.