Description: Finisher 1 elevator lower limit detection/ Finisher 2 stack tray lower limit detection. When the bin is shifted, the upper limit or the lower limit sensor is detected. / The elevator exceeds the lower limit.
Causes: Sensor defective Sorter/finisher control PWB abnormality
Remedy: Check sensor with SIM3-2.
Code: F1 05
Description: Finisher 1 elevator home / Finisher 2 stack tray sensor abnormality. The elevator does not detect the home position. / Stack tray sensors are turned on in the abnormal combination.
Causes: Sensor defective Sorter/finisher control PWB abnormality
Remedy: Check sensor with SIM3-2.
Code: F1 06
Description: Finisher shift motor abnormality. 1) Bin shift is not completed within 2.5 seconds after bin shift request
Causes: Motor lock Improper motor speed Overcurrent to motor Finisher control PWB defective
Remedy: Check bin shift motor operation with SIM3-4.
Code: F1 08
Description: Finisher staple shift motor trouble. Staple motor drive trouble
Causes: Motor lock Motor rpm abnormality Overcurrent to motor Finisher control PWB trouble
Remedy: Check the operation of the staple motor with SIM 3-3.
Code: F1 10
Description: Finisher staple unit operation trouble. Staple operation trouble
Causes: Motor lock Motor rpm abnormality Motor overcurrent Finisher control PWB trouble
Remedy: Check the staple motor operation with SIM 3-3.
Code: F1 11
Description: Finisher 1 pusher motor trouble / Finisher 2 boomerang rotation abnormality. Pusher motor trouble / Paddle solenoid abnormality
Causes: Motor lock / paddle solenoid operation abnormality / boomerang rotation sensor abnormality Motor rpm abnormality Motor overcurrent Finisher control PWB abnormality
Remedy: Check the finisher motor operation, the paddle solenoid operation with SIM 3-3 or check the boomerang rotation sensor with SIM 3-2.