Code: U2-12

Description: Adjustment value check sum error (Controller)
Adjustment data area check sum error
Causes: EEPROM trouble Control circuit trouble by noise Controller PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.

Code: U2-80

Description: EEPROM read/write error (Scanner)
Scanner EEPROM write error
Causes: EEPROM abnormality EEPROM which is not initialized is installed. Hang of control circuit due to noises Scanner PWB EEPROM access circuit abnormality
Remedy: Check that EEPROM is set properly. Record counter/adjustment values with the simulation to protect the data from being deleted. Cancel U2 trouble with SIM 16. Replace scanner PWB.

Code: U2-81

Description: Memory check sum error (Scanner)
Scanner memory check sum error
Causes: EEPROM trouble Control circuit freeze by noises Scanner PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is set properly. Record counter/adjustment values with the simulation to protect the data from being deleted. Cancel U2 trouble with SIM 16. Replace scanner PWB.

Code: U2-90

Description: EEPROM read/write error (PCU)
PCU EEPROM write error
Causes: EEPROM trouble EEPROM is not initialized. Hang of control circuit due to noises PCU PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.

Code: U2-91

Description: Memory check sum error (PCU)
PCU memory check sum error
Causes: EEPROM trouble EEPROM is not initialized. PCU PWB EEPROM access circuit trouble Uninitialized EEPROM installed.
Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.

Code: U6-00

Description: Desk/LCC communication trouble
Desk/LCC communication error Communication cable test error after turning on the power or exiting DIAG.
Causes: Improper connection or disconnection of connector and harness Desk control PWB trouble Control PWB (PCU) trouble Noise or interference
Remedy: Canceled by turning OFF/ON the power. Check connection of the harness and connector in the communication line.

Code: U6-01

Description: Desk/LCC No. 1 tray lift-up trouble
Desk/LCC No. 1 tray lift-up trouble
Causes: Sensor trouble Desk control PWB trouble Gear breakage Lift-up motor trouble
Remedy: Use DIAG (SIM4-2) to check the lift-up sensor detection. Use DIAG (SIM4-3) to check the lift-up motor operation.

Code: U6-02

Description: Desk No. 2 tray/LCC1 lift-up trouble
Desk No. 2 tray/LCC lift-up trouble
Causes: Sensor trouble Desk control PWB trouble Gear breakage Lift-up motor trouble
Remedy: Use DIAG (SIM4-2) to check the lift-up sensor detection. Use DIAG (SIM4-3) to check the lift-up motor operation.