Remedy: Case 1 Trouble position/cause "Bad connection of the toner density sensor, the process control PWB, and the PCU MAIN PWB" Remedy (Check) "Check connections of the toner density sensor, the process control PWB, and the PCU MAIN PWB." (Repair) Replace the toner density sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Process control PWB trouble Remedy (Check) Check the toner density sensor output level with SIM 25-1. (Repair) Replace the process control PWB. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) Check the toner density sensor output level with SIM 25-1. (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
Remedy: Case 1 Trouble position/cause "Bad connection of the toner density sensor, the process control PWB, and the PCU MAIN PWB" Remedy (Check) "Check connections of the toner density sensor, the process control PWB, and the PCU MAIN PWB." (Repair) Replace the toner density sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Process control PWB trouble Remedy (Check) Check the toner density sensor output level with SIM 25-1. (Repair) Replace the process control PWB. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) Check the toner density sensor output level with SIM 25-1. (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
Code: F2 44
Description: Image density sensor trouble (BLACK) (Transfer belt surface reflection abnormality)
Causes: "In the image density correction, the transfer belt surface is read by the image density sensor and the sensor gain is adjusted so that the output becomes a fixed value. However, the output of the specified range cannot be obtained even though the sensor gain is changed."
Remedy: Case 1 Trouble position/cause Image density sensor trouble Remedy (Check) "Check the image density sensor (dirt, output)(SIM44-2) / Check the image density sensor calibration plate. / Check the operation of the image density sensor calibration plate switching." (Repair) Clean or replace the image density sensor. / Clean or replace the image density sensor calibration plate. / Replace the image density sensor calibration plate switch solenoid. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause "Transfer belt trouble (dirt, scratch)" Remedy (Check) "Toner dispersion from the transfer belt, the OPC drum unit, and the developing unit" (Repair) Clean or replace the transfer belt. / Replace the transfer belt cleaner. / Clean the OPC drum and the developing unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUM PWB image density sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
Code: F2 45
Description: Image density sensor trouble (COLOR)(Calibration plate reflection abnormality)
Causes: "In the image density correction, the transfer belt surface is read by the image density sensor and the sensor gain is adjusted so that the output becomes a fixed value. However, the output of the specified range cannot be obtained even though the sensor gain is changed."
Remedy: Case 1 Trouble position/cause Image density sensor trouble Remedy (Check) "Check the image density sensor (dirt, output)(SIM44-2) / Check the image density sensor calibration plate. / Check the operation of the image density sensor calibration plate switching." (Repair) Clean or replace the image density sensor. / Clean or replace the image density sensor calibration plate. / Replace the image density sensor calibration plate switch solenoid. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause "Transfer belt trouble (dirt, scratch)" Remedy (Check) "Toner dispersion from the transfer belt, the OPC drum unit, and the developing unit" (Repair) Clean or replace the transfer belt. / Replace the transfer belt cleaner. / Clean the OPC drum and the developing unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUM PWB image density sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
Causes: The drum marking is not recognized. / The size and the number of drum markings are not specified ones.
Remedy: Case 1 Trouble position/cause "Drum marking sensor trouble (dirt, output)" Remedy (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. Remedy (Check) Check connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. (Repair) Repair or replace the cable and the connector between PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause "OPC drum surface dirt, scratch / A different type of OPC drum is installed." Remedy (Check) "Check dirt and scratches on the OPC drum surface, and the type of OPC drum." (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
Causes: The drum marking is not recognized. / The size and the number of drum markings are not specified ones.
Remedy: Case 1 Trouble position/cause "Drum marking sensor trouble (dirt, output)" Remedy (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. Remedy (Check) Check connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. (Repair) Repair or replace the cable and the connector between PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause "OPC drum surface dirt, scratch / A different type of OPC drum is installed." Remedy (Check) "Check dirt and scratches on the OPC drum surface, and the type of OPC drum." (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
Causes: The drum marking is not recognized. / The size and the number of drum markings are not specified ones.
Remedy: Case 1 Trouble position/cause "Drum marking sensor trouble (dirt, output)" Remedy (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. Remedy (Check) Check connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. (Repair) Repair or replace the cable and the connector between PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause "OPC drum surface dirt, scratch / A different type of OPC drum is installed." Remedy (Check) "Check dirt and scratches on the OPC drum surface, and the type of OPC drum." (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
Causes: The drum marking is not recognized. / The size and the number of drum markings are not specified ones.
Remedy: Case 1 Trouble position/cause "Drum marking sensor trouble (dirt, output)" Remedy (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. Remedy (Check) Check connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. (Repair) Repair or replace the cable and the connector between PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Case 4 Trouble position/cause "OPC drum surface dirt, scratch / A different type of OPC drum is installed." Remedy (Check) "Check dirt and scratches on the OPC drum surface, and the type of OPC drum." (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.