Các lỗi thường gặp

Code :
  • Code: A0-01
  • Description: PCU PWB ROM error
  • Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. PCU PWB trouble.
  • Remedy: Use SIM49-1 to perform the firmware version-up procedure again. Replace the PCU PWB.
  • Code: A0-02
  • Description: SCU PWB ROM error
  • Causes: The firmware version-up is not completed properly by interruption of the power during the version-up operation, etc. SCU PWB trouble.
  • Remedy: Use SIM49-1 to perform the firmware version-up procedure again. Replace the SCU PWB.
  • Code: A0-11
  • Description: Firmware version inconsistency (MFP - PCU)
  • Causes: Firmware combination error between the MFP and the PCU.
  • Remedy: Install the firmware in the all-firmware version-up mode.
  • Code: A0-15
  • Description: Incompatible DSK BOOT and program firmware
  • Causes: Installation of the normal firmware was performed with a security kit enable.
  • Remedy: Stop installation of the normal firmware.
  • Code: A0-20
  • Description: Conflict firmware and EEPROM data version (MFP)
  • Causes: Inconsistency between the MFP firmware version and the EEPROM data version.
  • Remedy: Check the combination of the firmware.
  • Code: A0-21
  • Description: Conflict firmware and EEPROM data version (PCU)
  • Causes: Inconsistency between the PCU firmware version and the EEPROM data version.
  • Remedy: Check the combination of the firmware.
  • Code: A0-22
  • Description: Conflict firmware and EEPROM data version (SCU)
  • Causes: Inconsistency between the SCU firmware version and the EEPROM data version.
  • Remedy: Check the combination of the firmware.
  • Code: E7-01
  • Description: MFP image data error
  • Causes: Image data transfer error in the MFPC PWB. MFPC PWB trouble.
  • Remedy: Check connection of the connector and the harness of the MFPC PWB. Check or replace the MFPC PWB.