Description: Inserter/EEPROM trouble Data read failure on turning on the power
Causes: EEPROM trouble Control circuit runaway due to noises Inserter PWB EEPROM access circuit trouble
Remedy: Case 1 Cause EEPROM trouble Control circuit runaway due to noises Check and remedy Check that the EEPROM is properly installed. Replace the inserter PWB. Case 2 Cause Inserter PWB EEPROM access circuit trouble Check and remedy Replace the inserter PWB.
Description: Toner control sensor open When the toner sensor output value is detected as smaller than 0.5V or greater than 4.5V for 3 times continuously at every 500ms after completion of the auto development adjustment.
Causes: Connector harness trouble Connector not connected.
Remedy: Check connection of the toner control sensor. Check connection of the connector harness to the main PWB. Check for disconnection of the harness.
Description: Toner supply abnormality Toner remains in the toner bottle when undertoner is detected by the toner concentration sensor in the developing unit.
Causes: Toner concentration sensor trouble. Toner remaining quantity sensor trouble. Connector harness trouble for the above sensors.
Remedy: Check connector of hopper unit toner motor (TM1) Check connector of toner bottle toner motor (TM2) Check connection of the connector harnesses to the main PWB. Check broken harness for above connections. Check output of the toner concentration sensor (SIM25-1). Check output of the toner remaining quantity sensor (SIM10-2).
Description: CRUM error Communication with the IC chip cannot be made. Data write failure to the CRUM or data read failure from the CRUM occurs 3 times continuously except for toner cartridge installation detection.
Description: Process control trouble (Photoconductor surface reflection rate abnormality) Before starting process control, the drum surface is read by the image density sensor to make the sensor gain adjustment so that the output is fixed to a certain level. Though the sensor gain is changed, the output is not fixed to a certain level.
Causes: Image density sensor trouble
Remedy: Use SIM 44-02 to perform the process control sensor gain adjustment.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.