Các lỗi thường gặp

Code :
  • Code: C26
  • Description: Peak detection error
  • Remedy: Does the exposure lamp light? (Perform the output check in the test mode: 03-267) YES 1. Check if the connectors on the CCD and SLG boards are disconnected. 2. Check if the shading correction plate is dirty. 3. Check if the conductor pattern on the CCD board is short- or open-circuited. 4. Check if the conductor pattern on the SLG board is short- or open-circuited. 5. Replace the lens unit. 6. Replace the SLG board. NO 1. Check if the connectors of the exposure lamp and inverter are disconnected. 2. Check the SLG board if the connector pin J9 is disconnected and the harness is short- or opencircuited. 3. Check if the conductor pattern on the SLG board is short- or open-circuited. 4. Replace the SLG board. 5. Replace the inverter. 6. Replace the exposure lamp.
  • Code: C27
  • Description: Carriage home position sensor not going OFF within a fixed time
  • Remedy: Are the carriages slightly moved to the feeding direction?/Are the carriages staying at a position other than home position? YES Check if the circuit of the SLG board is abnormal. NO 1. Check if the connector pin is disconnected and the harness is short- or open-circuited. 2. Check if the conductor pattern on the SLG board is short- or open-circuited. 3. Replace the SLG board.
  • Code: C28
  • Description: Carriage home position sensor not going ON within a fixed time
  • Remedy: Do the carriages make a big noise after they arrive at the home position? YES The carriage home position sensor is not turned ON. 1. Check if the connector of the sensor is disconnected. 2. Check if the circuit of the SLG board is abnormal. NO The carriages are stopped at the home position and do not move. 1. Check if the connector pins are disconnected and the harnesses are short- or open-circuited. 2. Check if the conductor pattern on the SLG board is short- or open-circuited. 3. Replace the SLG board.
  • Code: C36
  • Description: Abnormal main charger wire cleaner drive motor
  • Remedy: (1) Check if the main charger is not disconnected. (2) Check if the wire cleaner drive motor is driving. (3) Replace the LGC board.
  • Code: C37
  • Description: Abnormal transfer belt cam motor
  • Remedy: (1) Check if the connector of the transfer belt cam motor is not disconnected. (2) Check if the transfer belt contact/release switch is working properly. (3) Replace the transfer belt cam motor. (4) Replace the LGC board.
  • Code: C41
  • Description: Abnormal thermistor or heater at the power ON
  • Remedy: 1. Check the thermistors (1) Check if the connectors are disconnected. (2) Check if the center and side thermistors (front, rear) are in contact with the surface of the fuser roller properly? (3) Check if the harnesses of the center and side thermistors are open-circuited. 2. Check the IH control board and IH coil (1) Check if the IH coil is broken. (2) Check if the connector of the IH coil is disconnected. (3) Check if the thermostat is blown. (4) Check if the connectors on the IH control board are disconnected (AC input connector and LGC I/F connectors J552 and J553). (5) Check if the IH control board or the switching power supply unit are abnormal. • Replace the IH control board. 3. Check the LGC board (1) Check if the connector J334 is disconnected. (2) Check if the conductor pattern on the LGC board is short- or open-circuited. (3) Replace the LGC board. 4. Clear the status counter After repairing the matter which caused the error [C41], perform the following: (1) Turn ON the power while [0] and [8] are pressed simultaneously. (2) Enter “400” with the digital keys, then press the [START] key. (3) Change the current status counter value “1” or “2” to “0”, then press the [SET] key or [INTERRUPT] key (to cancel [C41]). (4) Turn the power OFF and then back ON. Make sure that the copier enters the normal standby state.
  • Code: C43
  • Description: Abnormal thermistor after abnormality judgment
  • Remedy: 1,2.3. Check the thermistors, IH control board, IH coil and LGC board Check the above components following the procedure 1, 2 and 3 for [C41]. 4. Clear the status counter Change the current status counter value (08-400) “4” to “0” for [C43] and “5”, “7” or “9” to “0” for [C44], taking the same procedure as that for [C41]. * The status counter value is as follows in the following cases. Change them to "0" respectively. • The error occurred during warming-up: "4" or "5" • The error occurred after the machine has become ready: "6" • The temperature detected by the center thermistor is 230°C or higher: "9" • The temperature detected by the side thermistor is 270°C or higher: "9"
  • Code: C44
  • Description: Abnormal fuser after abnormality judgment
  • Remedy: 1,2.3. Check the thermistors, IH control board, IH coil and LGC board Check the above components following the procedure 1, 2 and 3 for [C41]. 4. Clear the status counter Change the current status counter value (08-400) “4” to “0” for [C43] and “5”, “7” or “9” to “0” for [C44], taking the same procedure as that for [C41]. * The status counter value is as follows in the following cases. Change them to "0" respectively. • The error occurred during warming-up: "4" or "5" • The error occurred after the machine has become ready: "6" • The temperature detected by the center thermistor is 230°C or higher: "9" • The temperature detected by the side thermistor is 270°C or higher: "9"