Code :
  • Code: CD4
  • Description: Full toner bag
  • Remedy: (1) Check the toner bag. • Is the toner bag full? (2) Check the toner full detection sensor. • Is the tone full detection sensor working properly? • Is the connector not disconnected? (3) Check the used toner transport motor. • Is the used toner transport motor driving? • Does the pulley beside the motor become heavy when it is turned toward the direction of arrow (counterclockwise)? (4) Replace the LGC board. (5) Release the status counter. • Turn the power ON while pressing both the [0] and [8] keys. • Press the [START] key after inputting [399] with digital keys. • Change the status counter "1", "2" or "3" to "0" and press the [SET] or [INTERRUPT] key ([CD4] released). • Check if the copier becomes to a standby state normally when power is turned ON again. • In case that the used toner transport motor does not drive or [CD4] is not released when power is turned ON again, do the above procedure after manually turning the pulley beside the motor toward the direction of arrow (counterclockwise) several times.
  • Code: CD5
  • Description: Web motor signal path error
  • Remedy: (1) Check if the connector of the web motor and connector pins are not disconnected. (2) Check if the drawer connector and connector pins are not disconnected. (3) Check if the harness between the drawer connector and the web motor is not open-circuited. (4) Check if the connector of the LGC board and connector pins are not disconnected. (5) Check if the harness between the connector of the LGC board and the drawer connector is not opencircuited. (6) Replace the LGC board. (7) Replace the fuser unit.
  • Code: CE0
  • Description: Abnormal comparator
  • Remedy: Is any harness between the PLG board and galvanic mirror, PLG board and laser drive PC board and PLG board and H-Sync detection PC board open-circuited or any connector disconnected? Replace the harness. Reconnect the connector. 1. Replace the PLG board. 2. Replace the laser optical unit.
  • Code: CE1
  • Description: Beam sensor detection error
  • Remedy: Is any harness between the PLG board and galvanic mirror, PLG board and laser drive PC board and PLG board and H-Sync detection PC board open-circuited or any connector disconnected? Replace the harness. Reconnect the connector. 1. Replace the PLG board. 2. Replace the laser optical unit.
  • Code: CE2
  • Description: Sensor busy error
  • Remedy: Is any harness between the PLG board and galvanic mirror, PLG board and laser drive PC board and PLG board and H-Sync detection PC board open-circuited or any connector disconnected? Replace the harness. Reconnect the connector. 1. Replace the PLG board. 2. Replace the laser optical unit.
  • Code: CE3
  • Description: Primary scanning adjustment error
  • Remedy: Is any harness between the PLG board and galvanic mirror, PLG board and laser drive PC board and PLG board and H-Sync detection PC board open-circuited or any connector disconnected? Replace the harness. Reconnect the connector. 1. Replace the PLG board. 2. Replace the laser optical unit.
  • Code: CE4
  • Description: Abnormal window comparator
  • Remedy: Is any harness between the PLG board and galvanic mirror, PLG board and laser drive PC board and PLG board and H-Sync detection PC board open-circuited or any connector disconnected? Replace the harness. Reconnect the connector. 1. Replace the PLG board. 2. Replace the laser optical unit.
  • Code: E01
  • Description: Leading edge of paper not reaching the fuser exit sensor
  • Remedy: Open the jam access cover. Is there any paper on the transport path? YES Remove the paper. NO Is the fuser exit sensor working? (Perform the input check in the test mode: 03-[ENERGY SAVER]ON/[6]/[F]) NO 1. Check if the connector of the exit sensor is disconnected. 2. Check if the connector J335 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open-circuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the exit sensor. 6. Replace the LGC board. YES Is the registration motor working? (Perform the output check in the test mode: 03-108/158) NO 1. Check if the connector of the registration clutch is disconnected. 2. Check if the connector J341 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open-circuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the registration clutch. 6. Replace the LGC board. YES Check the registration roller. Replace it if it is worn out.