Code: SC822-3003

Description: Self-diagnostic error 3: HDD
Check performed when HDD is installed
Remedy: • HDD defective • HDD harness disconnected, defective • Controller board defective

Code: SC822-3004

Description: Self-diagnostic error 3: HDD
No response to the self-diagnostic command from the ASIC to the HDDs
Remedy: • HDD defective

Code: SC822-3013

Description: Self-diagnostic error 3: HDD
Mandolin does not respond, the HDD device remains BUSY for more than 31 s, or the BUSY signal does not drop within 6 s after the diagnostic command is issued to the HDDs
Remedy: • HDD defective • HDD connector loose or defective • Controller defective

Code: SC822-3014

Description: Self-diagnostic error 3: HDD
Error returned from HDD in response to the self-diagnostic command, Mandolin could not be located due to a read/write error at the HDD register.
Remedy: • HDD defective

Code: SC824

Description: Self-diagnostic error 4: NVRAM NVRAM device does not exist, NVRAM device is damaged, NVRAM socket damaged
Remedy: • NVRAM defective • Controller board defective • NVRAM backup battery exhausted • NVRAM socket damaged

Code: SC826-1501

Description: Self-diagnostic error 6: NVRAM (option NVRAM)
The difference between the 1 s measured for RTC in the NVRAM and the 1 s timeout of the CPU is out of range, or the NVRAM is not detected.
Remedy: • NVRAM defective • NVRAM installed incorrectly • Replace RTC backup battery

Code: SC826-15FE

Description: Self-diagnostic error 6: NVRAM (option NVRAM)
Backup battery error. Battery is exhausted or not within rated specification.
Remedy: • Replace RTC backup battery

Code: SC828

Description: Self-diagnostic error 7: ROM • Measuring the CRC for the boot monitor and operating system program results in an error. • A check of the CRC value for ROMFS of the entire ROM area results in an error.
Remedy: • Software defective • Controller board defective • ROM defective NOTE: For more details about this SC 833, SC834 error, execute SP5990 to print an SMC report so you can read the error code. The error code is not displayed on the operation panel. The additional error codes (0F30, 0F31, etc. are listed in the SMC report.