Code :
  • Code: 913
  • Description: DC pick motor overspeed error
  • Causes:
  • Remedy: • Check system board • Check autocompensator
  • Code: 914
  • Description: DC pick motor no encoder feedback
  • Causes:
  • Remedy: Check autocompensator assembly
  • Code: 917
  • Description: Problem with transfer— transfer servo start error.
  • Causes: • Check HVPS • Check system board • Check HVPS/input sensor/toner sensor cable.
  • Remedy:
  • Code: 920.01
  • Description: Hot roll took too long to heat up after transitioning to new enhanced mode (standby control only. Fuser page count between 0 and 99,999.
  • Causes: • Bad thermistor, circuit or cabling. • Fuser not receiving sufficient AC power. • Poor supply line voltage. • Low wattage or incorrect lamp. • Incorrect hot roll.
  • Remedy: See 920.xx
  • Code: 920.02
  • Description: Hot roll fell too far below the desired temperature while in standby. Fuser page between 0 and 99,999.
  • Causes: • Bad thermistor, circuit or cabling. • Fuser not receiving sufficient AC power. • Poor supply line voltage. • Low wattage or incorrect lamp. • Incorrect hot roll.
  • Remedy: See 920.xx
  • Code: 920.03
  • Description: Hot roll too cool when checking for slope change in standby. Fuser page count between 0 and 99,999.
  • Causes: • Bad thermistor, circuit or cabling. • Fuser not receiving sufficient AC power. • Poor supply line voltage. • Low wattage or incorrect lamp. • Incorrect hot roll.
  • Remedy: See 920.xx
  • Code: 920.04
  • Description: Hot roll too cool when heating to desired temperature after slope change (standby control only). Fuser page count between 0 and 99,999.
  • Causes: • Bad thermistor, circuit or cabling. • Fuser not receiving sufficient AC power. • Poor supply line voltage. • Low wattage or incorrect lamp. • Incorrect hot roll.
  • Remedy: See 920.xx
  • Code: 920.06
  • Description: Fuser is not increasing in temperature even though the lamp has been on for an extended time. Fuser page count between 0 and 99,999.
  • Causes: • Fuser is not receiving AC power. • Poor supply line voltage.
  • Remedy: See 920.xx