Các lỗi thường gặp

Code :
  • Code: 072-102
  • Description: IOT Option Regi On Jam Either of the following error codes is displayed in the UI. • 050-137 • 050-138 Cause: After the Tray 2 Path Sensor turned ON, the Regi. Sensor did not turn ON within the specified time.
  • Remedy: 1 Is there any foreign substances or bits of paper found on the paper transport path? Remove the foreign substances and bits of paper, etc. Go to Step 2. 2 Are the paper feed rolls installed properly? Go to Step 3. Reinstall the corresponding paper feed rolls 3 Are the paper feed rolls deformed or worn out? Replace the corresponding paper feed rolls Go to Step 4. 4 • Execute the Diag Digital Input 071-102 to check the operation of the REGISENSOR HVPS. • Is the REGI-SENSOR HVPS operating normally? Go to Step 5. Go to FIP 2.03 5 • Execute the Diag Digital Input [071-119] to check the operation of the Tray 2 Path Sensor. • Is the Tray 2 Path Sensor operating normally? Go to Step 6. Go to FIP 2.07 6 • Execute the Diag Digital Output 071-021 to check the operation of the Tray 2 TAKE AWAY CLUTCH. • Is the Tray 2 TAKE AWAY CLUTCH operating normally? Go to Step 7. Go to FIP 2.13 7 • Check the operation of the OPTIONAL TRAY MOTOR-ASSEMBLY • Execute the Diag Digital Output Tray 2: [071-009] to check the rotation of the OPTIONAL TRAY MOTOR-ASSEMBLY. • Is it working properly? Go to Step 8. Go to FIP 2.17 8 • Replace (Feeder Assembly). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
  • Code: 072-211
  • Description: Feeder 2 Error Cause: IOT Option Feeder2 Failure.
  • Remedy: 1 Check the operation of the OPTIONAL TRAY MOTOR ASSEMBLY (when the Optional Sheet Feeder is installed) • Execute the Diag Digital Output [071-009] to check the rotation of the OPTIONAL TRAY MOTOR ASSEMBLY. • Is it working properly? Go to Step 2. Go to FIP 2.17 2 Check the connections between the OPTIONAL TRAY PWB ASSEMBLY and the MCU PWB, as well as between the OPTIONAL TRAY PWB ASSEMBLY and the LVPS PWB. • Are the OPTIONAL TRAY HARNESS ASSEMBLY (P/J213P/J243, P/J24P/J243) and the HARNESS ASSEMBLY FEEDER DRAWER 1 (P/J243P/J419) connected securely? Go to Step 3. Securely connect the OPTIONAL FEEDER HARNESS ASSEMBLY FEEDER and the DRAWER 1 HARNESS ASSEMBLY 3 • Replace the OPTIONAL FEEDER HARNESS ASSEMBLY. • Does an error occur? Go to Step 4. Troubleshooting complete. 4 • Replace the DRAWER 1 FEEDER HARNESS ASSEMBLY . • Does an error occur? Go to Step 5. Troubleshooting complete. 5 • Replace (Optional Tray PWB Assembly) • Does an error occur? Go to Step 6. Troubleshooting complete. 6 • Replace (Feeder Assembly). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
  • Code: 073-211, 074-211
  • Description: 073-211 Feeder 3 Error 074-211 Feeder 4 Error Cause: 073-211: IOT Option Feeder3 Failure. 074-211: IOT Option Feeder4 Failure.
  • Remedy: 1 Check the operation of the OPTIONAL TRAY MOTOR ASSEMBLY • Execute the Diag Digital Output Tray 3:071- 012 / Tray 4:071-015 to check the rotation of the OPTIONAL TRAY MOTOR ASSEMBLY. • Is it working properly? Go to Step 2. Go to FIP 2.17 2 Check the connection between the OPTIONAL TRAY PWB ASSEMBLY (Upper) and the OPTIONAL TRAY PWB ASSEMBLY (Lower). • Are the FEEDER HARNESS ASSEMBLY DRAWER 2 (P/J423P/J4231) and the FEEDER HARNESS ASSEMBLY DRAWER 1 (P/J4231P/J419) connected securely? Go to Step 3. Securely connect the FEEDER HARNESS ASSEMBLY DRAWER 2 and the FEEDER HARNESS ASSEMBLY DRAWER 1 3 • Replace the FEEDER HARNESS ASSEMBLY DRAWER 2. • Does an error occur? Go to Step 4. Troubleshooting complete. 4 • Replace the FEEDER HARNESS ASSEMBLY DRAWER 1. • Does an error occur? Go to Step 5. Troubleshooting complete. 5 • Replace(Optional Tray PWB Assembly) • Does an error occur? Go to Step 6. Troubleshooting complete. 6 • Replace (Feeder Assembly). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
  • Code: 075-100
  • Description: MSI Misfeed Jam 050-134 is displayed in the UI. Cause: After the MSI Feed Solenoid turned ON, the Regi. Sensor did not turn ON within the specified time.
  • Remedy: 1 Is there any foreign substances or bits of paper found on the paper transport path? Remove the foreign substances and bits of paper, etc. Go to Step 2. 2 Are the paper feed rolls installed properly? Go to Step 3. Reinstall the corresponding paper feed rolls 3 Are the paper feed rolls deformed or worn out? Replace the corresponding paper feed rolls Go to Step 4. 4 • Execute the Diag Digital Input [071-102] to check the operation of the REGI-SENSOR HVPS. • Is the REGI-SENSOR HVPS operating normally? Go to Step 5. Go to FIP 2.03 5 • Execute the Diag Digital Output [071-004] to check the operation of the SOLENOID FEED MSI. • Is the SOLENOID FEED MSI operating normally? Go to Step 6. Go to FIP 2.14 6 • Execute the Diag Digital Output [071-001] to check the rotation of the MAIN DRIVE ASSEMBLY. • Is it working properly? Replace (MCU PWB) Go to FIP 2.15
  • Code: 077-101
  • Description: VSYNC ON Jam Cause: Detect VSYNC ON Jam.
  • Remedy: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (MCU PWB).
  • Code: 077-104
  • Description: Regi. Off Jam 050-130 is displayed in the UI. Cause: The Regi Sensor does not turn OFF within the specified time after the Regi Clutch turned On.
  • Remedy: 1 Is there any foreign substances or bits of paper found on the paper transport path? Remove the foreign substances and bits of paper, etc. Go to Step 2. 2 Are the paper feed rolls installed properly? Go to Step 3. Reinstall the corresponding paper feed rolls 3 Are the paper feed rolls deformed or worn out? Replace the corresponding paper feed rolls Go to Step 4. 4 • Execute the Diag Digital Input [071- 102] to check the operation of the REGISENSOR HVPS. • Is the REGI-SENSOR HVPS operating normally? Go to Step 5. Go to FIP 2.03 5 • Execute the Diag Digital Output [071- 006] to check the operation of the REGI. CLUTCH. • Is the REGI. CLUTCH operating normally? Go to Step 6. Go to FIP 2.10 6 • Execute the Diag Digital Output [071- 001] to check the rotation of the MAIN DRIVE ASSEMBLY. • Is it working properly? Replace (MCU PWB) Go to FIP 2.15
  • Code: 077-106, 077-108, 077-109
  • Description: 077-106 Exit On Jam 077-108 Exit Off early Jam 077-109 Exit Off Jam Cause: 077-106: Either of the following error codes is displayed in the UI. 050-130 - 050-132 - 050-142 The Exit Sensor does not turn ON within the specified time after the Regi Clutch turned On. 077-108: 050-130 is displayed in the UI. After the Exit Sensor turned ON, the Exit Sensor turned OFF before the specified time. 077-109: 050-130 is displayed in the UI. After the Regi. Sensor turned OFF, the Exit Sensor did not turn OFF within the specified time.
  • Remedy: 1 • Is there any foreign substances or bits of paper found on the paper transport path? Note: Make sure that the FUSING ASSEMBLY has cooled down before performing the operation. Remove the foreign substances and bits of paper, etc. Go to Step 2. 2 Are the paper feed rolls installed properly? Go to Step 3. Reinstall the corresponding paper feed rolls 3 Are the paper feed rolls deformed or worn out? Replace the corresponding paper feed rolls Go to Step 4. 4 • Execute the Diag Digital Input [071-103] to check the operation of the EXIT SENSOR. • Is the EXIT SENSOR operating normally? Go to Step 5. Go to FIP 2.01 5 • Execute the Diag Digital Input [071-102] to check the operation of the REGISENSOR HVPS. • Is the REGI-SENSOR HVPS operating normally? Go to Step 6. Go to FIP 2.03 6 • Execute the Diag Digital Output [071-007] to check the operation of the EXIT CLUTCH ASSEMBLY. • Is the EXIT CLUTCH ASSEMBLY operating normally? Go to Step 7. Go to FIP 2.08 7 • Execute the Diag Digital Output [071-006] to check the operation of the REGI. CLUTCH. • Is the REGI. CLUTCH operating normally? Go to Step 8. Go to FIP 2.10 8 • Execute the Diag Digital Output [071-001] to check the rotation of the MAIN DRIVE ASSEMBLY. • Is it working properly? Replace (MCU PWB) Go to FIP 2.15
  • Code: 077-215, 077-217
  • Description: 077-215 IOT Duplex Error 077-217 Duplex Miss Configuration Cause: Duplex Unit Configuration error is detected.
  • Remedy: Turn the power Off and On to check that the error recurs, then replace the Duplex Unit.