Các lỗi thường gặp

Code :
  • Code: 03-130-00, 03-950-00
  • Description: Tray 4 Communications Fault
  • Causes: 03-130-00 A communication error has occurred between the MCU Board and Tray 4. 03-950-00 A communication error has occurred between the MCU Board and Tray 4.
  • Remedy: • Lock the feeder to Tray 3. • Reseat the IOT and Tray 3 on the Feeder. • Check for obstructions blocking the option harnesses.
    Cycle system power. The error message is displayed. Y↓ N→Complete. Remove the IOT and Tray 3 from the Feeder. Check feeder option harness continuity. The harnesses are undamaged. Y↓ N→Replace the damaged option harness. Check the IOT option connector. The harness is undamaged. Y↓ N→Replace the Lower Option Harness. Replace these components in order until the error is corrected. 1. Feeder Board, PL 8.30 Item 7 2. MCU Board, PL 3.10 Item 3
  • Code: 03-140-00, 03-960-00
  • Description: Tray 5 Communications Fault
  • Causes: 03-140-00 A communication error has occurred between the MCU Board and Tray 5. 03-960-00 A communication error has occurred between the MCU Board and Tray 5.
  • Remedy: • Lock the feeder to Tray 5. • Reseat the IOT, Tray 3, and Tray 4 on the Feeder. • Check for obstructions blocking the option harnesses.
    Cycle system power. The error message is displayed. Y↓ N→Complete. Remove the IOT, Tray 3, and Tray 4 from the Feeder. Check feeder option harness continuity. The harnesses are undamaged. Y↓ N→Replace the damaged option harness. Check the IOT option harness. The harness is undamaged. Y↓ N→Replace the Lower Option Harness. Replace these components in order until the error is corrected. 1. Feeder Board, PL 8.30 Item 7 2. MCU Board, PL 3.10 Item 3
  • Code: 03-150-00, 03-965-00
  • Description: Tray 6 Communications Fault
  • Causes: 03-150-00 A communication error has occurred between the MCU Board and Tray 6. 03-965-00 A communication error has occurred between the MCU Board and Tray 6.
  • Remedy: • Lock the feeder to Tray 6. • Reseat the IOT, Tray 3, Tray 4, and Tray 5 on the Feeder. • Check for obstructions blocking the option connections.
    Cycle system power. The error message is displayed. Y↓ N→Complete. Remove the IOT, Tray 3, Tray 4, and Tray 5 from the Feeder. Check feeder option connector continuity. The harnesses are undamaged. Y↓ N→Replace the damaged option harness. Check the IOT option connector. The harness is undamaged. Y↓ N→Replace the Lower Option Harness. Replace these components in order until the error is corrected. 1. Feeder Board, PL 8.30 Item 7 2. MCU Board, PL 3.10 Item 3
  • Code: 03-160-00, 03-990-00
  • Description: HCF Communications Fault
  • Causes: 03-160-00 A communication error has occurred between the MCU Board and the HCF. 03-990-00 A communication error has occurred between the MCU Board and the HCF.
  • Remedy: • Lock the feeder to the HCF. • Reseat the IOT, Tray 3, Tray 4, on the HCF. • Check for obstructions blocking the option connections.
    Cycle system power. The error message is displayed. Y↓ N→Complete. Remove the IOT and installed feeders from the HCF. Check the HCF option harness. The harness is undamaged. Y↓ N→Replace the damaged option harness. Check feeder option harness continuity for all feeders. The harnesses are undamaged. Y↓ N→Replace the damaged option harness. Check the IOT Lower Option Harness. The harness is undamaged. Y↓ N→Replace the Lower Option Harness. Replace these components in order until the error is corrected. 1. HCF Control Board, PL 7.25 Item 18 2. MCU Board, PL 3.10 Item 3
  • Code: 03-305-00
  • Description: Configuration Card Not Present
  • Causes: The Configuration Card is missing from its slot on the rear panel.
  • Remedy: • Reseat the Configuration Card. • Cycle system power.
    Cycle system power. The error message is displayed. Y↓ N→Complete. Remove and inspect the Configuration Card. The card is undamaged. Y↓ N→Replace the Configuration Card. Check the configuration card holder. The holder is secure. Y↓ N→Secure the holder to the IP Board. Install the card. Replace these components in order until the error is corrected. 1. Configuration Card, PL 3.10 Item 6 2. IP Board, PL 3.10 Item 2
  • Code: 03-315-00, 03-325-00
  • Description: Manufacturer ID
  • Causes: 03-315-00 The Configuration Card is invalid for this system. 03-325-00 The Configuration Card is invalid for this system.
  • Remedy: • Reseat the Configuration Card. • Cycle system power.
    Cycle system power. The error message is displayed. Y↓ N→Complete. Remove and inspect the Configuration Card. The card is undamaged. Y↓ N→Replace the Configuration Card. Replace these components in order until the error is corrected. 1. Configuration Card, PL 3.10 Item 6 2. IP Board, PL 3.10 Item 2
  • Code: 03-335-00
  • Description: Configuration Card Not Configured
  • Causes: The Configuration Card did not initialize.
  • Remedy: • Reseat the Configuration Card. • Cycle system power.
    Cycle system power. The error message is displayed. Y↓ N→Complete. Remove and inspect the Configuration Card. The card is undamaged. Y↓ N→Replace the Configuration Card. Replace these components in order until the error is corrected. 1. Configuration Card, PL 3.10 Item 6 2. IP Board, PL 3.10 Item 2
  • Code: 03-410-00
  • Description: Tray 2 Paper Mismatch
  • Causes: Media size setting for Tray 2 differs from the media size reported by the Tray 2 Size Switch.
  • Remedy: • Check media size settings for the tray from the Control Panel. • Reset the tray side and rear guides. • Check for obstructions blocking the Size Switch.
    Cycle system power. The error message is displayed. Y↓ N→Complete. Remove Tray 2 and inspect the Size Switch. The Size Switch is undamaged. Y↓ N→Replace the Size Switch. Inspect the Tray 2 end guide. The end guide operates the Size Switch actuators. Y↓ N→Replace the Tray, Select dC330 codes 07-220, 07-230, 07-240. The switches are operational (high/low). Y↓ N→Replace the Size Switch. Replace these components in order until the error is corrected. 1. Size Switch, PL 3.10 Item 9 2. Tray, PL 7.10 Item 23 3. MCU Board, PL 3.10 Item 3
 < 1 2 3 4 5 >  Last ›