Các lỗi thường gặp

Code :
  • Code: 062-320
  • Description: Scanner Error Scanning error
  • Causes: • IIT Assembly (PL51.1.3) • IP Board (PL18.1.22)
  • Remedy: 1 Check the IIT Assembly connection Check the connection between the IIT Assembly and the IP Board. Are P/J1401 and P/J1501 connected securely? Go to step 2. Connect P/J1401 and P/J1501 securely. 2 Check after replacing the IIT Assembly Replace the IIT Assembly. Does the error still occur? Replace the IP Board. Finished.
  • Code: 062-321
  • Description: Unexecutable error. (carriage is at the locked position, etc.)
  • Causes: • IIT Assembly (PL51.1.3) • IP Board (PL18.1.22)
  • Remedy: 1 Check the IIT Assembly connection Check the connection between the IIT Assembly and the IP Board. Are P/J1401 and P/J1501 connected securely? Go to step 2. Connect P/J1401 and P/J1501 securely. 2 Check after replacing the IIT Assembly Replace the IIT Assembly. Does the error still occur? Replace the IP Board. Finished.
  • Code: 062-322
  • Description: Parameter error
  • Causes: • IIT Assembly (PL51.1.3) • IP Board (PL18.1.22)
  • Remedy: 1 Check the IIT Assembly connection Check the connection between the IIT Assembly and the IP Board. Are P/J1401 and P/J1501 connected securely? Go to step 2. Connect P/J1401 and P/J1501 securely. 2 Check after replacing the IIT Assembly Replace the IIT Assembly. Does the error still occur? Replace the IP Board. Finished.
  • Code: 062-360
  • Description: HPSensor Error Carriage home position error
  • Causes: • IIT Assembly (PL51.1.3) • IP Board (PL18.1.22)
  • Remedy: 1 Check the IIT Assembly connection Check the connection between the IIT Assembly and the IP Board. Are P/J1401 and P/J1501 connected securely? Go to step 2. Connect P/J1401 and P/J1501 securely. 2 Check after replacing the IIT Assembly Replace the IIT Assembly. Does the error still occur? Replace the IP Board. Finished.
  • Code: 062-371
  • Description: IIT failure Lamp error
  • Causes: • IIT Assembly (PL51.1.3) • IP Board (PL18.1.22)
  • Remedy: 1 Check the IIT Assembly connection Check the connection between the IIT Assembly and the IP Board. Are P/J1401 and P/J1501 connected securely? Go to step 2. Connect P/J1401 and P/J1501 securely. 2 Check after replacing the IIT Assembly Replace the IIT Assembly. Does the error still occur? Replace the IP Board. Finished.
  • Code: 062-393
  • Description: CcdAsic Error CcdAsic communication error
  • Causes: • IIT Assembly (PL51.1.3) • IP Board (PL18.1.22)
  • Remedy: 1 Check the IIT Assembly connection Check the connection between the IIT Assembly and the IP Board. Are P/J1401 and P/J1501 connected securely? Go to step 2. Connect P/J1401 and P/J1501 securely. 2 Check after replacing the IIT Assembly Replace the IIT Assembly. Does the error still occur? Replace the IP Board. Finished.
  • Code: 062-790
  • Description: Copy Limit
  • Causes: • IIT Assembly (PL51.1.3) • IP Board (PL18.1.22)
  • Remedy: 1 Check the IIT Assembly connection Check the connection between the IIT Assembly and the IP Board. Are P/J1401 and P/J1501 connected securely? Go to step 2. Connect P/J1401 and P/J1501 securely. 2 Check after replacing the IIT Assembly Replace the IIT Assembly. Does the error still occur? Replace the IP Board. Finished.
  • Code: 071-100
  • Description: IOT Tray1 Misfeed JAM Detect Tray1 Misfeed JAM
  • Causes: • Regi Sensor [Regi Chute Assembly] (PL15.2.1) • Feed Clutch (PL15.2.6) • Paper Transport Motor [Drive Assembly] (PL3.1.1) • Feed Roller Assembly (PL15.2.7) • Tray Retard Holder Assembly (PL9.1.3) • Regi Harness Assembly (PL15.2.8) • MCU Board (PL18.1.13)
  • Remedy: 1 Check the Tray 1 installation Is Tray 1 installed properly? Go to step 2. Install Tray 1 properly. 2 Check the paper path Are there any foreign objects, or paper pieces, etc. on the paper path? Remove the foreign objects, or paper pieces, etc. Go to step 3. 3 Check the paper feed roller Is the paper feed roller (the roller on the possible causative parts list) installed properly? Go to step 4. Reinstall the paper feed roller. 4 Check the paper feed roller Is the paper feed roller (the roller on the possible causative parts list) deformed or worn out? Replace the paper feed roller. Go to step 5. 5 Check the Regi Sensor operation Execute Digital Input diagnostic test 071-103, and check the Regi Sensor operation. Does the Regi Sensor function normally? Go to step 6. 6 Check the Feed Clutch operation Execute Digital Output diagnostic test 071-008, and check the Feed Clutch operation. Does the Feed Clutch function normally? Go to step 7. 7 Check the Paper Transport Motor operation Execute Digital Output diagnostic test 071-004, and check the Paper Transport Motor rotation. Does the Paper Transport Motor function normally? Replace the MCU Board.