Description: LPH FFC Connect Posi Fault M. The image data (M) cannot be received normally from the MCU.
Remedy: Enter dc122 Fault History. Check whether 361.375 LPH Chip Fail M has occurred. Has Fail 361.375 occurred? Y↓ N→Replace the following parts in sequence: • LPH Unit (M) • LPH Cable Assembly • LPH Rear PWB (M) • MCU PWB Proceed to RAP 361.375.
Code: 361.392
Description: LPH FFC Connect Posi Fault C. The image data (C) cannot be received normally from the MCU.
Remedy: Enter dc122 Fault History. Check whether 361.376 LPH Chip Fail C has occurred. Has Fail 361.376 occurred? Y↓ N→Replace the following parts in sequence: • LPH Unit (C) • LPH Cable Assembly • LPH Rear PWB (C) • MCU PWB Proceed to RAP 361.376.
Code: 361.393
Description: LPH FFC Connect Posi Fault K. The image data (K) cannot be received normally from the MCU.
Remedy: Enter dc122 Fault History. Check whether 361.377 LPH Chip Fail K has occurred. Has Fail 361.377 occurred? Y↓ N→Replace the following parts in sequence: • LPH Unit (K) • LPH Cable Assembly • LPH Rear PWB (K) • MCU PWB Proceed to RAP 361.377.
Code: 361.394
Description: LPH FFC Connect Nega Fault Y. The image data (Y) cannot be received normally from the MCU.
Remedy: Enter dc122 Fault History. Check whether 361.374 LPH Chip Fail Y has occurred. Has Fail 361.374 occurred? Y↓ N→Replace the following parts in sequence: • LPH Unit (Y) • LPH Cable Assembly • LPH Rear PWB (Y) • MCU PWB Proceed to RAP 361.374.
Code: 361.395
Description: LPH FFC Connect Nega Fault M. The image data (M) cannot be received normally from the MCU.
Remedy: Enter dc122 Fault History. Check whether 361.375 LPH Chip Fail M has occurred. Has Fail 361.375 occurred? Y↓ N→Replace the following parts in sequence: • LPH Unit (M) • LPH Cable Assembly • LPH Rear PWB (M) • MCU PWB (7545/56) Proceed to RAP 361.375.
Code: 361.396
Description: LPH FFC Connect Nega Fault C. The image data (C) cannot be received normally from the MCU.
Remedy: Enter dc122 Fault History. Check whether 361.376 LPH Chip Fail C has occurred. Has Fail 361.376 occurred? Y↓ N→Replace the following parts in sequence: • LPH Unit (C) • LPH Cable Assembly • LPH Rear PWB (C) • MCU PWB Proceed to RAP 361.376.
Code: 361.397
Description: LPH FFC Connect Nega Fault K. The image data (K) cannot be received normally from the MCU.
Remedy: Enter dc122 Fault History. Check whether 361.377 LPH Chip Fail K has occurred. Has Fail 361.377 occurred? Y↓ N→Replace the following parts in sequence: • LPH Unit (K) • LPH Cable Assembly • LPH Rear PWB (K) • MCU PWB Proceed to RAP 361.377.
Code: 361.398
Description: BITZ1 Initialize Fault The Bitz1 initialization error was detected. This is an error where the CPU is unable to access the memory and the register of the ASIC BITZ (image processing chip for Y and M) that is installed on the MCU PWB.
Remedy: Enter dc122 Fault History. Check whether an LPH-related Fail has occurred. Has any Chain No. 361 Fail occurred? Y↓ N→Replace the following parts in sequence: • LPH Cable Assembly • MCU PWB Go to the appropriate RAP.