Description: RC Data Linearity Fail M. The result from adding the skew/bow correction value to the M color linearity correction value has exceeded the settable range. (This is a hidden failure. The LPH Slow Scan linearity cannot be guaranteed and Data is only recorded in history.)
Remedy: Check that the value stored in LPH (M) EEPROM is correct. Has any M color related Chain No. 061 Fail occurred? Y↓ N→Check the following: • Check that the value of dc131 NVM Read/Write [760-024] is "0". • The Imaging Unit (M) for improper installation. If no problems are found, replace the following parts in sequence: • Imaging (M) • LPH Unit (M) • Rear Holder Assembly (M) Replace the LPH Unit (M). If the problem persists, replace the MCU PWB.
Description: RC Data Linearity Fail C. The result from adding the skew/bow correction value to the C color linearity correction value has exceeded the settable range. (This is a hidden failure. The LPH Slow Scan linearity cannot be guaranteed and Data is only recorded in history.)
Remedy: Check that the value stored in LPH (C) EEPROM is correct. Has any C color related Chain No. 061 Fail occurred? Y↓ N→Check the following: • Check that the value of dc131 NVM Read/Write [760-024] is "0". • The Imaging Unit (C) for improper installation. If no problems are found, replace the following parts in sequence: • Imaging Unit (C) • LPH Unit (C) • Rear Holder Assembly (C) Replace the LPH Unit (C). If the problem persists, replace the MCU PWB.
Description: RC Data Linearity Fail K. The result from adding the skew/bow correction value to the K color linearity correction value has exceeded the settable range. (This is a hidden failure. The LPH Slow Scan linearity cannot be guaranteed and Data is only recorded in history.)
Remedy: Check that the value stored in LPH (K) EEPROM is correct. Has any K color related Chain No. 061 Fail occurred? Y↓ N→Check the following: • Check that the value of dc131 NVM Read/Write [760-024] is "0". • The Imaging Unit (K) for improper installation. If no problems are found, replace the following parts in sequence: • Imaging Unit (K) • LPH Unit (K) • Rear Holder Assembly (K) Replace the LPH Unit (K). If the problem persists, replace the MCU PWB.
Description: Waste Toner Bottle Near Full. The Waste Toner Bottle Full Sensor detected Near Full state.
Remedy: The Waste Toner Bottle needs to be replaced soon. Replace the Waste Toner Bottle (PL 8.2) as required. If the problem persists, check the Waste Toner Bottle Full Sensor. Turn the power On and enter the Diag mode. Turn On dc330 Component Control [091-201]. Use a sheet of paper, etc. to block/clear the light path to the Waste Toner Bottle Full Sensor. Does the display change between High/Low? Y↓ N→Use Transmissive Sensor RAP to check the Waste Toner Bottle Full Sensor. Press the Stop button and turn the power Off. Replace the MCU PWB.