Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Xerox WorkCentre 6605 — Trang 3/15

Code: 024-947, 024-948

Description: Tray Detached Tray 1 : 947 Tray 2 : 948
Causes:
Remedy: Insert the tray.

Code: 026-720

Description: USB Memory Full Writing to USB memory failed.
Causes:
Remedy: Replace the IP Board.

Code: 026-721

Description: USB Memory Write Error Writing to USB memory failed.
Causes:
Remedy: Replace the IP Board.

Code: 027-446

Description: IPv6 duplicate At start-up, detect duplicate IPv6 address on network.
Causes:
Remedy: Replace the IP Board.

Code: 027-452

Description: IPv4 duplicate At start-up, detect duplicate IPv4 address on network.
Causes:
Remedy: Replace the IP Board.

Code: 042-313

Description: IOT Fan Motor Failure Detect Fan Motor Error
Causes: • Main Fan (PL4.1.13) • Top Harness Assembly (PL18.2.5) • LVPS (PL18.1.34) • MCU Board (PL18.1.13)
Remedy: 1 Check the Main Fan operation Execute Digital Output diagnostic test 042-001, and check the Main Fan rotation. Does the Main Fan function normally? Replace the MCU Board. Go to step 2. 2 Check the Main Fan installation Rotate the Main Fan manually. Is there an overload? Reinstall the Main Fan appropriately. Go to step 3. 3 Check the Main Fan connection Check the connection between the Main Fan and the LVPS. Is P/J503 connected securely? Go to step 4. Reconnect P/J503 securely. 4 Check the connections between the LVPS and the MCU Board Are P/J501 and P/J29 connected securely? Go to step 5. Reconnect P/J501 and P/J29 securely. 5 Check the continuity between the LVPS and the MCU Board Is each cable of P/J501<=>P/J29 continuous? Go to step 6. Replace the Top Harness Assembly. 6 Check after replacing the Main Fan Replace the Main Fan. Does the error still occur? Replace the LVPS. Finished.

Code: 042-325

Description: IOT Motor Failure Detect Motor Failure
Causes: • Main Motor [Drive Assembly] (PL3.1.1) • Drive Harness Assembly (PL18.2.2) • Top Harness Assembly (PL18.2.5) • LVPS (PL18.1.34) • MCU Board (PL18.1.13)
Remedy: 1 Check the Main Motor operation Execute Digital Output diagnostic test 071-001, and check the Main Motor rotation. Does the Main Motor function normally? Replace the MCU Board. Go to step 2. 2 Check the Main Motor connection Check the connection between the Main Motor and the LVPS, and the connection between the Main Motor and the MCU Board. Are P/J311, P/J509, P/J171 and P/J17 connected securely? Go to step 3. Connect P/J311, P/J509, P/J171, and P/J17 securely. 3 Check the continuity between the Main Motor and the MCU Board Is each cable of P/J171<=>P/J17 continuous? Go to step 4. Replace the Drive Harness Assembly. 4 Check the continuity between the Main Motor and the LVPS Is each cable of P/J311<=>P/J509 continuous? Go to step 5. Replace the Top Harness Assembly. 5 Check the power to the Main Motor (+24 VDC) Close the interlock switch(es), and check if the voltage between the LVPS ground and the P/J509-1 pin is about +24 VDC. Replace the Drive Assembly. Replace the LVPS.

Code: 042-326

Description: IOT Motor Failure Detect Motor Failure
Causes: • Paper Transport Motor [Drive Assembly] (PL3.1.1) • Drive Harness Assembly (PL18.2.2) • Top Harness Assembly (PL18.2.5) • LVPS (PL18.1.34) • MCU Board (PL18.1.13)
Remedy: 1 Check the Paper Transport Motor operation Execute Digital Output diagnostic test 071-004, and check the Paper Transport Motor rotation. Does the Paper Transport Motor function normally? Replace the MCU Board. Go to step 2. 2 Check the Paper Transport Motor connection Check the connection between the Paper Transport Motor and the LVPS, and the connection between the Paper Transport Motor and the MCU Board. Are P/J312, P/J509, P/J172, and P/J17 connected securely? Go to step 3. Connect P/J312, P/J509, P/J172, and P/J17 securely. 3 Check the continuity between the Paper Transport Motor and the MCU Board Is each cable of P/J172<=>P/J17 continuous? Go to step 4. Replace the Drive Harness Assembly. 4 Check the continuity between the Paper Transport Motor and the LVPS Is each cable of P/J312<=>P/J509 continuous? Go to step 5. Replace the Top Harness Assembly. 5 Check the power to the Paper Transport Motor (+24 VDC) Close the interlock switch(es), and check if the voltage between the LVPS ground and the P/J509-3 pin is about +24 VDC. Replace the Drive Assembly. Replace the LVPS.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie