Display: Cover is Open Close the Fuser Cover which can be found behind the Back Cover of the machine.
Description: The eject sensor detected that the fuser cover ASSY was open.
Causes: 1 Paper jam at the eject actuator 2 Eject actuator that has come off or that has been caught 3 Eject sensor PCB harness connection failure 4 Fuser cover ASSY installation failure 5 Eject sensor PCB failure 6 Main PCB failure
Description: Immediately after power-ON or the joint cover ASSY was closed, GRID current error detected that no drum unit (Color) was set.
Causes: 1 Dirt on the GRID terminals of the main body 2 Dirt on the terminal of the high-voltage power supply PCB 3 High-voltage power supply PCB failure 4 Main PCB failure
Description: Immediately after power-ON or the joint cover ASSY was closed, GRID current error detected that one of the drum units (Color) was not set.
Causes: 1 Dirt on the GRID terminals of the main body 2 Dirt on the terminal of the high-voltage power supply PCB 3 High-voltage power supply PCB failure 4 Main PCB failure
Description: Immediately after power-ON or the joint cover ASSY was closed, GRID current error detected that no drum unit (Black) was set.
Causes: 1 Dirt on the GRID terminals of the main body 2 Dirt on the terminal of the high-voltage power supply PCB 3 High-voltage power supply PCB failure 4 Main PCB failure
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.