Display: Print Unable 02 Turn the power off and then back on again.
Description: Synchronization signal from the main motor cannot be detected. Or the main motor speed is unstable after a set period of time.
Causes: 1 Main motor harness connection failure 2 Harness connection failure between the low-voltage power supply PCB and main PCB 3 Main motor failure 4 Low-voltage power supply PCB failure 5 Main PCB failure
Display: Print Unable 02 Turn the power off and then back on again.
Description: Synchronization signal from the process motor cannot be detected. Or the process motor speed is unstable after a set period of time.
Causes: 1 Process motor harness connection failure 2 Harness connection failure between the low-voltage power supply PCB and main PCB 3 Process motor failure 4 Low-voltage power supply PCB failure 5 Main PCB failure
Display: Print Unable 05 Turn the power off and then back on again.
Description: The center thermistor of the fuser unit does not reach the specified temperature within the specified time.
Causes: 1 Connection failure of the center or side thermistor harness of the fuser unit 2 Connection failure of the heater harness of the fuser unit 3 Harness connection failure of the eject sensor PCB 4 Harness connection failure of the low-voltage power supply PCB 5 Eject sensor PCB failure 6 Fuser unit failure 7 Low-voltage power supply PCB failure 8 Main PCB failure
Display: Print Unable 05 Turn the power off and then back on again.
Description: The center thermistor of the fuser unit does not reach the specified temperature within the specified time.
Causes: 1 Connection failure of the center or side thermistor harness of the fuser unit 2 Connection failure of the heater harness of the fuser unit 3 Harness connection failure of the eject sensor PCB 4 Harness connection failure of the low-voltage power supply PCB 5 Eject sensor PCB failure 6 Fuser unit failure 7 Low-voltage power supply PCB failure 8 Main PCB failure
Display: Print Unable 05 Turn the power off and then back on again.
Description: The center thermistor of the fuser unit detected a temperature higher than the specified value.
Causes: 1 Connection failure of the center or side thermistor harness of the fuser unit 2 Connection failure of the heater harness of the fuser unit 3 Harness connection failure of the eject sensor PCB 4 Harness connection failure of the low-voltage power supply PCB 5 Eject sensor PCB failure 6 Fuser unit failure 7 Low-voltage power supply PCB failure 8 Main PCB failure
Display: Print Unable 05 Turn the power off and then back on again.
Description: After the center thermistor of the fuser unit was normally heated, it detected a temperature lower than the specified value.
Causes: 1 Connection failure of the center or side thermistor harness of the fuser unit 2 Connection failure of the heater harness of the fuser unit 3 Harness connection failure of the eject sensor PCB 4 Harness connection failure of the low-voltage power supply PCB 5 Eject sensor PCB failure 6 Fuser unit failure 7 Low-voltage power supply PCB failure 8 Main PCB failure
Display: Print Unable 05 Turn the power off and then back on again.
Description: The center thermistor of the fuser unit detected a temperature rise greater than the specified value within a set period of time.
Causes: 1 Connection failure of the center or side thermistor harness of the fuser unit 2 Connection failure of the heater harness of the fuser unit 3 Harness connection failure of the eject sensor PCB 4 Harness connection failure of the low-voltage power supply PCB 5 Eject sensor PCB failure 6 Fuser unit failure 7 Low-voltage power supply PCB failure 8 Main PCB failure
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.