Description: The cartridge motor Y (M11) is found to have an over-current condition.
Causes: The cartridge motor is faulty.
Code: E025-0201
Description: The cartridge motor M (M12) is fount to have an over-current condition.
Causes: The cartridge motor is faulty.
Code: E025-0301
Description: The cartridge motor C (M13) is found to have an over-current condition.
Causes: The cartridge motor is faulty.
Code: E025-0401
Description: The cartridge motor Bk (M14) is found to have an over-current condition.
Causes: The cartridge motor is faulty.
Code: E032
Description: The Copy Data Controller-A1 or NE controller counter mechanism fails to operate.
Causes: The Copy Data Controller-A1 or the NE controller is faulty or has an open circuit. The system controller PCB is faulty.
Code: E041-0001
Description: The fault was detected while the lifter was moving up. The deck lifter position sensor (PS104) does not detect the lifter within 60 sec after the deck lifter UP signal is generated. The output of the deck paper sensor (PS107) is ‘0’ when the output of the deck lifter position sensor (PS104) and that of the deck paper level sensor (PS108) are ‘1’.
Causes: The deck lifter motor (M102) is faulty. The deck driver PCB is faulty. A connected device is faulty. The deck lifter position sensor (PS104) is faulty. The deck paper sensor (PS107) is faulty.
Code: E041-0002
Description: The fault was detected while the lifter was moving down. The deck lifter position sensor (PS104) does not detect the lifter within 60 sec after the deck lifter UP signal is generated. The output of the deck paper sensor (PS107) is ‘0’ when the output of the deck lifter position sensor (PS104) and that of the deck paper level sensor (PS108) are ‘1’.
Causes: The deck lifter motor (M102) is faulty. The deck driver PCB is faulty. A connected device is faulty. The deck lifter position sensor (PS104) is faulty. The deck paper sensor (PS107) is faulty.
Code: E043
Description: The PLL lock signal (DMPLK) remains ‘1’ for 2 sec or more after the deck main motor drive signal is generated.
Causes: The deck main motor (M101) is faulty. The deck driver PCB is faulty. A connected device is faulty.