Description: An error has occurred in the communication between CPUs of the reader controller PCB and the control panel.
Causes: An error has occurred in the communication between CPUs of the reader controller PCB and the control panel.
Code: E244
Description: x=0: Pickup assembly PCB, 1: Serial driver PCB, 2: Duplex driver PCB y=0 to 7: Port of each PCB xy01 Connection check error When the main power switch is turned on, communication with each PCB cannot be established. xy02 Parity error After communication with each PCB has been established, a parity error has occurred continuously 5 times. xy04 Sub station reset response time-out error When the main power switch is turned on, each PCB cannot be reset (reset processing error). xy05 Connection check result response time-out error When the main power switch is turned on, communication with each PCB cannot be established. xy06 Transmission end response time-out error After communication has been established with each PCB, the absence of responce has occurred continuously 5 times. (monitoring at tall times)
Causes: The pickup assembly PCB is faulty. The serial driver PCB is faulty. The duplex driver PCB is faulty. The DC controller PCB is faulty.
Code: E351
Description: An error has occurred in the anti-counterfeit PCB.
Causes: An error has occurred in the anti-counterfeit PCB.
Code: E401
Description: The sensor does not turn on and off twice or more within 1 sec.
Causes: The pickup motor (M1) fails to rotate. The pickup roller sensor (S5) is faulty.
Code: E402
Description: The number of clock pulses within 200 msec is lower than a specific value.
Causes: The belt motor (M3) fails to rotate. The belt motor lock sensor (S10) is faulty.
Code: E404
Description: The number of clock pulses within 200 msec is lower than a specific value.
Causes: The feed motor (M2) fails to rotate. The feed motor clock sensor (S9) is faulty.
Code: E411
Description: In the absence of paper, the output of the sensor is 2.3 V or higher.
Causes: The original tray power sensor (S1) is faulty. The registration sensor (S3) is faulty.
Code: E500
Description: The communication between the host machine and the sorter is disrupted. (This error is detected by the host machine.)