Description: An open circuit has occurred in the waste toner motor.
Causes: The waste toner feedscrew has locked. The waste toner feed motor is faulty. The transfer high-voltage PCB is faulty. The serial driver PCB is faulty. The DC controller PCB is faulty.
Code: E014-
Description: The target speed cannot be attained even when the frequency of the motor drive pulse is changed.
Causes: The belt motor (M15) is faulty. The belt motor drive system has an excess load. The drum drive AC generation PCB is faulty. The transfer drive AC generation PCB is faulty. The DC controller PCB is faulty.
Code: E014-0001
Description: The target speed cannot be attained even when the frequency of the motor drive pulse is increased to the upper limit.
Causes: The belt motor (M15) is faulty. The belt motor drive system has an excess load. The drum drive AC generation PCB is faulty. The transfer drive AC generation PCB is faulty. The DC controller PCB is faulty.
Code: E014-0002
Description: The target speed cannot be attained even when the frequency of the motor drive pulse is decreased to the lower limit.
Causes: The belt motor (M15) is faulty. The belt motor drive system has an excess load. The drum drive AC generation PCB is faulty. The transfer drive AC generation PCB is faulty. The DC controller PCB is faulty.
Code: E014-0003
Description: The encoder signal is not generated by the motor.
Causes: The belt motor (M15) is faulty. The belt motor drive system has an excess load. The drum drive AC generation PCB is faulty. The transfer drive AC generation PCB is faulty. The DC controller PCB is faulty.
Code: E014-0004
Description: The motor rotates in the direction opposite the desired direction.
Causes: The belt motor (M15) is faulty. The belt motor drive system has an excess load. The drum drive AC generation PCB is faulty. The transfer drive AC generation PCB is faulty. The DC controller PCB is faulty.
Code: E014-0009
Description: An error has occurred in the communication with the DC controller PCB.
Causes: The belt motor (M15) is faulty. The belt motor drive system has an excess load. The drum drive AC generation PCB is faulty. The transfer drive AC generation PCB is faulty. The DC controller PCB is faulty.
Code: E020
Description: XX=01: Y, XX=02: M, XX=03: C, XX=04: Bk (XX indicates the developing assembly color) XXA0During printing sequence, the difference between the maximum value and the minimum value of SIGNAL (9 samplings) is 0.2 V (10) or less. XX80 During printing sequence, the value of INIT-SIGNAL entered as part of initial settings has dropped to 2.344 V (120) or lower. XX81 During printing sequence, the value of INIT-SIGNAL entered as part of initial settings has risen to 2.656 V (136) or higher. XX90 During printing sequence, the correction value for INIT-SIGNAL has changed to 0 (in service mode, ADJUST>DENS>SIGG-Y/M/ C/K). XX91 During printing sequence, the correction value for INIT-SIGNAL has changed to 255 (in service mode, ADJUST>DENS>SIGG-Y/ M/C/K). XXB0 During printing sequence, the value of SIGNAL obtained by sampling and averaging is 0.43 V (22) or lower. XXB1 During printing sequence, the value of SIGNAL obtained by sampling and averaging is 4.9 V (250) or higher. XXD0During printing sequence, the value of SIGNAL remains higher than INIT-SIGNAL entered as part of initial settings by 4.71 V (240) or more continuously for 10 prints. XXE0 During printing sequence, the value of SIGNAL remains lower than INIT-SIGNAL entered as part of initial settings by 0.98 V (50) or more continuously for 10 prints.
Causes: The ATR sensor connector is disconnected. The developing cylinder/stirring screw fails to rotate.