Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon i-SENSYS LBP7110Cw

Code: E000-0000

Description: Fixing unit startup defect
The detected temperature of the main thermistor does not rise after the heater is energised.
Causes: Main thermistor broken wire, fixer heater broken wire, DC controller PCB defect.
Remedy: • Check the connector of the fixing unit, DC controller PCB, fixing power supply unit. • Replace the fixing film unit. • Replace the fixing power supply unit. • Replace the DC controller PCB.

Code: E001-0000

Description: Abnormally high temperature in fixing unit.
The detected temperature of the main thermistor is abnormally high.
Causes: Main thermistor defect, DC controller PCB defect.
Remedy: • Check the connector of the fixing unit, DC controller PCB, fixing power supply unit. • Replace the fixing film unit. • Replace the fixing power supply unit. • Replace the DC controller PCB.

Code: E003-0000

Description: Abnormally low temperature in fixing unit.
The detected temperature of the main thermistor becomes lower than the specified one.
Causes: Fixing power supply unit defect, main thermistor broken wire, DC controller PCB defect
Remedy: • Check the connector of the fixing unit, DC controller PCB, fixing power supply unit. • Replace the fixing film unit. • Replace the fixing power supply unit. • Replace the DC controller PCB.

Code: E004-0000

Description: Abnormality in fixing unit power supply drive circuitry.
Zero cross signal could not be detected within specified time limit.
Causes: Fixing control circuitry defect.
Remedy: • Check the connector of the fixing power supply unit, DC controller PCB, fixing power supply unit. • Replace the low-voltage power supply PCB.

Code: E012-0000

Description: Motor startup abnormality.
ITB motor speed detection signal frequency does not reach specified frequency after starting to drive the ITB motor.
Causes: ITB motor defect, DC controller PCB defect
Remedy: • Check the connector of the ITB motor, DC controller PCB. • Replace ITB motor. • Replace DC controller PCB.

Code: E012-0001

Description: Motor startup abnormality
ITB motor speed detection signal frequency reaches the specified frequency but is then out of synch after 2 sec. or longer of operation.
Causes: ITB motor defect, DC controller PCB defect
Remedy: • Check the connector of the ITB motor, DC controller PCB. • Replace ITB motor. • Replace DC controller PCB.

Code: E015-0001

Description: Developing roller release operation defect
After the specified time from rotating the main motor for the developing roller depress/release, the output of the developing home position sensor does not change.
Causes: Developing home position sensor defect, Main motor defect, DC controller PCB defect
Remedy: • Check the connector of the developer home position sensor, main motor, DC controller PCB • Replace the developer home position sensor • Replace the main motor • Replace the DC controller PCB

Code: E020-0000

Description: Density sensor abnormality
Not enough light received upon image density detection.
Causes: Soiled density detection sensor, density detection sensor defect, DC controller PCB defect, toner cartridge defect
Remedy: • Check the connector of the DC controller PCB. • Replace ITB unit • Replace DC controller PCB • Replace toner cartridge
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie