Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon imageCLASS LBP7780Cdn

Code: E000-0000

Description: Fixing startup failure
Causes: The detection temperature of the main thermistor did not increase after start of the power distribution to the heater.
Remedy: • Replace the fixing assembly. • Replace the DC controller PCB

Code: E001-0000

Description: Abnormal high temperature in fixing
Causes: The main thermistor detected a temperature of higher than 255 degree C.
Remedy: • Replace the fixing assembly. • Replace the DC controller PCB.

Code: E001-0001

Description: Abnormal high temperature in fixing
Causes: The sub thermistor detected a temperature of higher than 290 degree C.
Remedy: • Replace the fixing assembly. • Replace the DC controller PCB.

Code: E001-0004

Description: Abnormal high temperature in fixing
Causes: The sub thermistor 2 detected a temperature exceeding a specified temperature.
Remedy: • Replace the fixing assembly. • Replace the DC controller PCB.

Code: E003-0000

Description: Abnormal low temperature in fixing
Causes: The main thermistor detected a temperature of lower than 120 degree C for more than 1 second when 20 seconds elapsed after start of the power distribution to the heater.
Remedy: • Replace the fixing assembly. • Replace the DC controller PCB.

Code: E003-0001

Description: Abnormal low temperature in fixing
Causes: The sub thermistor detected a temperature of lower than 80 degree C for more than 2 seconds when 20 seconds elapsed after start of the power distribution to the heater.
Remedy: • Replace the fixing assembly. • Replace the DC controller PCB.

Code: E003-0004

Description: Abnormal low temperature in fixing
Causes: The sub thermistor 2 detected a temperature lower than a specified temperature
Remedy: • Replace the fixing assembly. • Replace the DC controller PCB.

Code: E004-0000

Description: Fixing assembly drive circuit failure
Causes: 43 to 57Hz could not be detected continuously for more than 5 seconds when zero cross detection started.
Remedy: • Check the contact of the connector between the fixing assembly and the low-voltage power supply PCB. • Replace the low-voltage power supply PCB.