Causes: Optical assembly error (Scanner motor rotation failure)
Remedy: • Check the contact of the connector between the laser scanner unit and the DC controller. • Replace the laser scanner unit.
Code: E196-0000
Description: Invalid RFU execution requested
Causes: D-con update for the host machine or the optional cassette is not completed.
Remedy: Replace the DC controller PCB
Code: E196-0001
Description: Invalid RFU execution requested
Causes: D-con update for the optional cassette is not completed.
Remedy: Replace the DC controller PCB
Code: E197-0002
Description: Engine FN Error
Causes: Error in DC Controller software
Remedy: 1. Turn OFF and then ON the power. 2. Download the Dcon firmware again by Updater. 3. Replace the DC controller PCB
Code: E198-0000
Description: DC controller memory failure
Causes: • A checksum failure is found in the block where specific information of the DC controller PCB is saved. • A communication error occurred when reading the specific information of the DC controller PCB from the NVRAM at power-on.
Remedy: If the failure cannot be removed by turning the power OFF/ON, replace the DC controller PCB.