  • Code: E110-0001
  • Description: Optical assembly error (Scanner motor)
  • Causes: Optical assembly error (Scanner motor rotation failure)
  • Remedy: • Check the contact of the connector between the laser scanner unit and the DC controller. • Replace the laser scanner unit.
  • Code: E196-0000
  • Description: Invalid RFU execution requested
  • Causes: D-con update for the host machine or the optional cassette is not completed.
  • Remedy: Replace the DC controller PCB
  • Code: E196-0001
  • Description: Invalid RFU execution requested
  • Causes: D-con update for the optional cassette is not completed.
  • Remedy: Replace the DC controller PCB
  • Code: E197-0002
  • Description: Engine FN Error
  • Causes: Error in DC Controller software
  • Remedy: 1. Turn OFF and then ON the power. 2. Download the Dcon firmware again by Updater. 3. Replace the DC controller PCB
  • Code: E198-0000
  • Description: DC controller memory failure
  • Causes: • A checksum failure is found in the block where specific information of the DC controller PCB is saved. • A communication error occurred when reading the specific information of the DC controller PCB from the NVRAM at power-on.
  • Remedy: If the failure cannot be removed by turning the power OFF/ON, replace the DC controller PCB.
  • Code: E245
  • Description: System Error
  • Causes: System Error
  • Remedy: Contact the sales companies.
  • Code: E246
  • Description: System Error
  • Causes: System Error
  • Remedy: Contact the sales companies.
  • Code: E247
  • Description: System Error
  • Causes: System Error
  • Remedy: Contact the sales companies.