Causes: Power supply fan failure The fan did not rotate even when 12 seconds elapsed after the motor rotation start order was received.
Remedy: • Reconnect the connector J21 on the DC controller PCB and the connector J106 on the low-voltage power supply unit. • If the voltage between the connectors J21-2 and J25-2 on the DC controller PCB is changed from 0V to approximately 24V immediately after the printer is turned on, replace the power supply fan.
Description: Drum phase control sensor failure warning
Causes: Yellow drum phase control sensor failure warning • A slit was not detected for 4 seconds after slit detection started. • An abnormal slit width was detected.
Remedy: • Check the YMC drum drive gear. • Replace the YMC drum HP sensor (PS13).
Description: Drum phase control sensor failure warning
Causes: Magenta drum phase control sensor failure warning • A slit was not detected for 4 seconds after slit detection started. • An abnormal slit width was detected.
Remedy: • Check the YMC drum drive gear. • Replace the YMC drum HP sensor (PS13).
Description: Drum phase control sensor failure warning
Causes: Cyan drum phase control sensor failure warning • A slit was not detected for 4 seconds after slit detection started. • An abnormal slit width was detected.
Remedy: • Check the YMC drum drive gear. • Replace the YMC drum HP sensor (PS13).
Description: Drum phase control sensor failure warning
Causes: Black drum phase control sensor failure warning • A slit was not detected for 4 seconds after slit detection started. • An abnormal slit width was detected.
Remedy: • Check the Bk drum drive gear. • Replace the Bk drum HP sensor (PS12).
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.