Description: Aligning plate home position error
The aligning plate home position sensor does not turn ON when the aligning plate motor has been driven for 500 pulses.
Remedy: 1. The aligning plate home position sensor (PI5) is faulty. 2. The aligning plate drive mechanism is faulty. 3. The aligning motor (M5) is faulty. 4. The saddle stitcher controller PCB is faulty.
Description: Aligning plate home position error
The aligning plate home position sensor does not turn OFF when the aligning plate motor has been driven for 50 pulses.
Remedy: 1. The aligning plate home position sensor (PI5) is faulty. 2. The aligning plate drive mechanism is faulty. 3. The aligning motor (M5) is faulty. 4. The saddle stitcher controller PCB is faulty.
Description: Stitcher (rear) home position error
The stitching home position sensor does not turn ON when the stitch motor (rear) has been driven backward for 0.5 sec.
Remedy: 1. The stitcher home position sensor (rear) (SW5) is faulty. 2. The stitcher (rear) is faulty. 3. The saddle stitcher controller PCB is faulty.
Description: Stitcher (rear) home position error
The stitching home position sensor does not turn OFF when the stitch motor (rear) has been driven forward for 0.5 sec.
Remedy: 1. The stitcher home position sensor (rear) (SW5) is faulty. 2. The stitcher (rear) is faulty. 3. The saddle stitcher controller PCB is faulty.
Description: Stitcher (front) home position error
The stitching home position sensor does not turn ON when the stitch motor (front) has been driven forward for 0.5 sec.
Remedy: 1. The stitcher home position sensor (front) (SW7) is faulty. 2. The stitcher (front) is faulty. 3. The saddle stitcher controller PCB is faulty.
Description: Stitcher (front) home position error
The stitching home position sensor does not turn OFF when the stitch motor (front) has been driven backward for 0.5 sec.
Remedy: 1. The stitcher home position sensor (front) (SW7) is faulty. 2. The stitcher (front) is faulty. 3. The saddle stitcher controller PCB is faulty.
Description: Paper pushing plate home position error
The paper pushing plate home position sensor does not turn ON when the paper pushing plate motor has been driven for 0.5 sec.
Remedy: 1. The paper pushing plate home position sensor (PI14), paper pushing plate top position sensor (PI15), and paper pushing plate motor clock sensor (PI1) is faulty. 2. The paper pushing plate drive mechanism is faulty. 3. The paper pushing plate motor (M8) is faulty. 4. The saddle stitcher controller PCB is faulty.
Description: Paper pushing plate home position error
The paper pushing plate home position sensor does not turn OFF when the paper pushing plate motor has been driven for 150 ms.
Remedy: 1. The paper pushing plate home position sensor (PI14), paper pushing plate top position sensor (PI15), and paper pushing plate motor clock sensor (PI1) is faulty. 2. The paper pushing plate drive mechanism is faulty. 3. The paper pushing plate motor (M8) is faulty. 4. The saddle stitcher controller PCB is faulty.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.