Code: E025 0120

Description: Bottle Motor error (Y). Rotation of bottle was detected while the Toner Bottle Motor (Y) was OFF.
Remedy: [Related parts] • Harnesses from the Bottle Motor (YM) to the DC Controller PCB 1. Bottle Motor (YM) (M04) to Relay Connector (2P) (Unit of replacement: CABLE, BOTTLE DRIVE MOTOR) 2. Relay Connector (2P) to DC Controller PCB (UN04/J127) (Unit of replacement: CABLE, TONER BOTTLE) • Harness between the Toner Supply Sensor (Y) (PS26/J1059) and DC Controller PCB (UN04/J127) (Unit of replacement: CABLE, TONER BOTTLE) • Toner Supply Sensor (Y) • Bottle Drive Unit (YM) (Unit of replacement: BOTTLE DRIVE ASSEMBLY, Y, M) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E025 0168

Description: No toner detection error (Y). The state without toner was detected although the recovery sequence was performed for 5 times after replacement of the Toner Container (Y).
Remedy: [Related parts] • Toner Container (Y) • Bottle Drive Unit (YM) (Unit of replacement: BOTTLE DRIVE ASSEMBLY, Y, M) • Developing Unit (Y) (UN21) (Unit of replacement: DEVELOPING ASSEMBLY, Y) ITB Rail Rear Unit (Unit of replacement: I.T.B. RAIL ASSEMBLY, REAR) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: E025 0210

Description: Bottle Motor error (M). The Toner Supply Sensor (M) did not detect change for 1 sec or longer while the Bottle Motor (YM) was rotated at toner supply.
Remedy: [Related parts] • Harnesses from the Bottle Motor (YM) to the DC Controller PCB 1. Bottle Motor (YM) (M04) to Relay Connector (2P) (Unit of replacement: CABLE, BOTTLE DRIVE MOTOR) 2. Relay Connector (2P) to DC Controller PCB (UN04/J127) (Unit of replacement: CABLE, TONER BOTTLE) • Harness between the Toner Supply Sensor (M) (PS27/J1060) and DC Controller PCB (UN04/J127) (Unit of replacement: CABLE, TONER BOTTLE) • Toner Supply Sensor (M) • Bottle Drive Unit (YM) (Unit of replacement: BOTTLE DRIVE ASSEMBLY, Y, M) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E025 0220

Description: Bottle Motor error (M). Rotation of bottle was detected while the Toner Bottle Motor (M) was OFF.
Remedy: [Related parts] • Harnesses from the Bottle Motor (YM) to the DC Controller PCB 1. Bottle Motor (YM) (M04) to Relay Connector (2P) (Unit of replacement: CABLE, BOTTLE DRIVE MOTOR) 2. Relay Connector (2P) to DC Controller PCB (UN04/J127) (Unit of replacement: CABLE, TONER BOTTLE) • Harness between the Toner Supply Sensor (M) (PS27/J1060) and DC Controller PCB (UN04/J127) (Unit of replacement: CABLE, TONER BOTTLE) • Toner Supply Sensor (M) • Bottle Drive Unit (YM) (Unit of replacement: BOTTLE DRIVE ASSEMBLY, Y, M) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E025 0268

Description: No toner detection error (M). The state without toner was detected although the recovery sequence was performed for 5 times after replacement of the Toner Container (M).
Remedy: [Related parts] • Toner Container (M) • Bottle Drive Unit (YM) (Unit of replacement: BOTTLE DRIVE ASSEMBLY, Y, M) • Developing Unit (M) (UN22) (Unit of replacement: DEVELOPING ASSEMBLY, M) ITB Rail Rear Unit (Unit of replacement: I.T.B. RAIL ASSEMBLY, REAR) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: E025 0310

Description: Bottle Motor error (C). The Toner Supply Sensor (C) did not detect change for 1 sec or longer while the Bottle Motor (CK) was rotated at toner supply.
Remedy: [Related parts] • Harnesses from the Bottle Motor (CK) to the DC Controller PCB 1. Bottle Motor (CK) (M05) to Relay Connector (2P) (Unit of replacement: CABLE, BOTTLE DRIVE MOTOR) 2. Relay Connector (2P) to DC Controller PCB (UN04/J127) (Unit of replacement: CABLE, TONER BOTTLE) • Harness between the Toner Supply Sensor (C) (PS28/J1061) and the DC Controller PCB (UN04/J127) (Unit of replacement: CABLE, TONER BOTTLE) • Toner Supply Sensor (C) • Bottle Drive Unit (CK) (Unit of replacement: BOTTLE DRIVE ASSEMBLY, C, K) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E025 0320

Description: Bottle Motor error (C). Rotation of bottle was detected while the Toner Bottle Motor (C) was OFF
Remedy: [Related parts] • Harnesses from the Bottle Motor (CK) to the DC Controller PCB 1. Bottle Motor (CK) (M05) to Relay Connector (2P) (Unit of replacement: CABLE, BOTTLE DRIVE MOTOR) 2. Relay Connector (2P) to DC Controller PCB (UN04/J127) (Unit of replacement: CABLE, TONER BOTTLE) -Harness between the Toner Supply Sensor (C) (PS28/J1061) and the DC Controller PCB (UN04/J127) (Unit of replacement: CABLE, TONER BOTTLE) • Toner Supply Sensor (C) • Bottle Drive Unit (CK) (Unit of replacement: BOTTLE DRIVE ASSEMBLY, C, K) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E025 0368

Description: No toner detection error (C). The state without toner was detected although the recovery sequence was performed for 5 times after replacement of the Toner Container (C).
Remedy: [Related parts] • Toner Container (C) • Bottle Drive Unit (CK) (Unit of replacement: BOTTLE DRIVE ASSEMBLY, C, K) • Developing Unit (C) (UN23) (Unit of replacement: DEVELOPING ASSEMBLY, C) ITB Rail Rear Unit (Unit of replacement: I.T.B. RAIL ASSEMBLY, REAR) [Remedy] Check/replace the related harness/cable, connector and parts.