Description: CL Drum Motor error. The specified speed could not be maintained for 0.5 consecutive sec although it became the specified speed at least once from the startup of the CL Drum Motor in the Main Drive Unit. (The detection timing varies depending on the paper feed conditions.)
Remedy: [Related parts] • Harness between the CL Drum Motor (M03/J1103) and the DC Controller PCB (UN04/J129) (Unit of replacement: CABLE, MAIN DRIVE) • Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) • CL Drum Motor (M03) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check whether the gears of the Main Drive Unit can be rotated by hand. a. If they cannot be rotated, replace the Main Drive Unit. b. If they can be rotated, check the harness between the CL Drum Motor and the DC Controller PCB. 2. Measure the both ends of the fuse in the Low Voltage Power Supply PCB using a tester. a. If the measurement value is less than 1 ohm (conduction state), 1. Replace the CL Drum Motor. 2. Replace the DC Controller PCB. b. If the measurement value is 1 ohm or higher (non conduction state), replace the Low Voltage Power Supply PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: E012 0003
Description: CL Drum Motor error. There was no FG signal input for 0.3 sec from the startup of the CL Drum Motor in the Main Drive Unit.
Remedy: [Related parts] • Harness between the CL Drum Motor (M03/J1103) and the DC Controller PCB (UN04/J129) (Unit of replacement: CABLE, MAIN DRIVE) • Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) • CL Drum Motor (M03) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check whether the gears of the Main Drive Unit can be rotated by hand. a. If they cannot be rotated, replace the Main Drive Unit. b. If they can be rotated, check the harness between the CL Drum Motor and the DC Controller PCB. 2. Measure the both ends of the fuse in the Low Voltage Power Supply PCB using a tester. a. If the measurement value is less than 1 ohm (conduction state), 1. Replace the CL Drum Motor. 2. Replace the DC Controller PCB. b. If the measurement value is 1 ohm or higher (non conduction state), replace the Low Voltage Power Supply PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: E013 0001
Description: Waste Toner Feed Motor error. After rotation speed of the Waste Toner Feed Motor was detected when the motor was driven, it was detected that the speed was not at the specified speed for 2 consecutive sec.
Remedy: [Related parts] • Harnesses from the DC Controller PCB to the Waste Toner Feed Motor 1. DC Controller PCB (UN04/J132) to Relay Connector (13P) (Unit of replacement: CABLE, CASSETTE SIZE) 2. Relay Connector (13P) to Waste Toner Feed Motor (J1044) (Unit of replacement: CABLE, WASTE TONER SENSOR) • Waste Toner Container (Unit of replacement: WASTE TONER CASE ASSEMBLY) • Waste Toner Feed Unit (Unit of replacement: WASTE TONER PAPER FEED ASS'Y) • Waste Toner Feed Motor (M17) (Unit of replacement: WASTE TONER PAPER FEED ASS'Y) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Pull out the Waste Toner Container to check if the toner in the container is full. If the waste toner is full, remove the toner clogged in the Waste Toner Pipe. 2. Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: E014 0001
Description: Fixing Motor error. It did not become the specified speed for 0.5 consecutive sec although 0.7 sec have passed from the startup of the Fixing Motor
Remedy: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Motor 1. DC Controller PCB (UN04/J122) to Relay Connector (8P) (Unit of replacement: CABLE, FEED) 2. Relay Connector (8P) to Fixing Motor (M09/J1019) (Unit of replacement: FIXING DRIVE ASSEMBLY) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Gears in the Fixing Unit 1. Cam Gear (Unit of replacement: CAM/GEAR, 3T/21T) 2. Pressure Roller Gear (Unit of replacement: GEAR, 36T) • Fixing Motor (M09) (Unit of replacement: FIXING DRIVE MOTOR ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check that the Fixing Unit is pushed into the host machine so the handle is locked. 2. Remove the Fixing Unit, and rotate the Cam Gear and the Pressure Roller Gear by hand to visually check that there is no bent or missing teeth or abnormal abrasion (edge of the gear is no longer tooth-shaped). 3. Replace the Fixing Unit. 4. Check the harness between the DC Controller PCB and the Fixing Motor. 5. Measure the both ends of the fuse in the Low Voltage Power Supply PCB using a tester. a. If the measurement value is less than 1 ohm (conduction state), 1. Replace the Fixing Motor. 2. Replace the DC Controller PCB. b. If the measurement value is 1 ohm or higher (non conduction state), replace the Low Voltage Power Supply PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: E014 0002
Description: Fixing Motor error. The specified speed could not be maintained for 0.5 consecutive sec although it became the specified speed at least once from the startup of the Fixing Motor.
Remedy: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Motor 1. DC Controller PCB (UN04/J122) to Relay Connector (8P) (Unit of replacement: CABLE, FEED) 2. Relay Connector (8P) to Fixing Motor (M09/J1019) (Unit of replacement: FIXING DRIVE ASSEMBLY) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Gears in the Fixing Unit 1. Cam Gear (Unit of replacement: CAM/GEAR, 3T/21T) 2. Pressure Roller Gear (Unit of replacement: GEAR, 36T) • Fixing Motor (M09) (Unit of replacement: FIXING DRIVE MOTOR ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check that the Fixing Unit is pushed into the host machine so the handle is locked. 2. Remove the Fixing Unit, and rotate the Cam Gear and the Pressure Roller Gear by hand to visually check that there is no bent or missing teeth or abnormal abrasion (edge of the gear is no longer tooth-shaped). 3. Replace the Fixing Unit. 4. Check the harness between the DC Controller PCB and the Fixing Motor. 5. Measure the both ends of the fuse in the Low Voltage Power Supply PCB using a tester. a. If the measurement value is less than 1 ohm (conduction state), 1. Replace the Fixing Motor. 2. Replace the DC Controller PCB. b. If the measurement value is 1 ohm or higher (non conduction state), replace the Low Voltage Power Supply PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: E014 0003
Description: Fixing Motor error. There was no FG signal input for 0.3 sec from the startup of the Fixing Motor.
Remedy: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Motor 1. DC Controller PCB (UN04/J122) to Relay Connector (8P) (Unit of replacement: CABLE, FEED) 2. Relay Connector (8P) to Fixing Motor (M09/J1019) (Unit of replacement: FIXING DRIVE ASSEMBLY) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Gears in the Fixing Unit 1. Cam Gear (Unit of replacement: CAM/GEAR, 3T/21T) 2. Pressure Roller Gear (Unit of replacement: GEAR, 36T) • Fixing Motor (M09) (Unit of replacement: FIXING DRIVE MOTOR ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check that the Fixing Unit is pushed into the host machine so the handle is locked. 2. Remove the Fixing Unit, and rotate the Cam Gear and the Pressure Roller Gear by hand to visually check that there is no bent or missing teeth or abnormal abrasion (edge of the gear is no longer tooth-shaped). 3. Replace the Fixing Unit. 4. Check the harness between the DC Controller PCB and the Fixing Motor. 5. Measure the both ends of the fuse in the Low Voltage Power Supply PCB using a tester. a. If the measurement value is less than 1 ohm (conduction state), 1. Replace the Fixing Motor. 2. Replace the DC Controller PCB. b. If the measurement value is 1 ohm or higher (non conduction state), replace the Low Voltage Power Supply PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: E020 01A8
Description: ATR Sensor (Y) output error. The output value of the ATR Sensor (Y) in the Developing Unit (Y) did not fall within the range between 38 and 214 for 2 consecutive times during printing.
Remedy: [Related parts] • Harnesses from the ATR Sensor (Y) to the DC Controller PCB 1. ATR Sensor (Y) (UN21/J1050) to Developing Unit (Y) (J1040) (Unit of replacement: CABLE, DEVELOPING) 2. Developing Unit (Y) (J1040) to Relay Connector (4P) (Unit of replacement: CABLE, RELAY) 3. Relay Connector (4P) to DC Controller PCB (UN04/J128) (Unit of replacement: CABLE, SENSOR) • Developing Unit (Y) (Unit of replacement: DEVELOPING ASSEMBLY, Y) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Code: E020 01B8
Description: ATR Sensor (Y) output error.The output value did not exceed 120 although the control voltage of the ATR Sensor (Y) in the Developing Unit (Y) was increased to 192 or higher, or it did not fall below 120 although the voltage was decreased to 42 at initialization.
Remedy: [Related parts] • Harnesses from the ATR Sensor (Y) to the DC Controller PCB 1. ATR Sensor (Y) (UN21/J1050) to Developing Unit (Y) (J1040) (Unit of replacement: CABLE, DEVELOPING) 2. Developing Unit (Y) (J1040) to Relay Connector (4P) (Unit of replacement: CABLE, RELAY) 3. Relay Connector (4P) to DC Controller PCB (UN04/J128) (Unit of replacement: CABLE, SENSOR) • Developing Unit (Y) (Unit of replacement: DEVELOPING ASSEMBLY, Y) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES