Causes: Reception incomplete was detected consecutively in communication between the host machine and the finisher.
Remedy: a. STAPLE/BOOKLET FINISHER-Y1 [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN1/J110), the Relay Path Unit and the Finisher Controller PCB - Harnesses connecting the Relay PCB (UN5/J403), the Relay Path Unit and the Finisher Controller PCB - DC Controller PCB (UN1) - Relay PCB (UN5) - Relay Path Unit - Finisher Controller PCB b. INNER FINISHER-H1 [Related parts] - Harness between the DC Controller PCB (UN1/J110) and the Finisher Controller PCB - Harness between the Relay PCB (UN5/J403) and the Finisher Controller PCB - DC Controller PCB (UN1) - Relay PCB (UN5) - Finisher Controller PCB [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES - After replacement of the Finisher Controller PCB, refer to "Adjustments> Adjustment when Replacing the Parts" in the Service Manual for the Finisher.
Code: 713-0022-05
Description: Finisher communication error
Causes: An undefined error was detected consecutively in communication between the host machine and the finisher.
Remedy: a. STAPLE/BOOKLET FINISHER-Y1 [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN1/J110), the Relay Path Unit and the Finisher Controller PCB - Harnesses connecting the Relay PCB (UN5/J403), the Relay Path Unit and the Finisher Controller PCB - DC Controller PCB (UN1) - Relay PCB (UN5) - Relay Path Unit - Finisher Controller PCB b. INNER FINISHER-H1 [Related parts] - Harness between the DC Controller PCB (UN1/J110) and the Finisher Controller PCB - Harness between the Relay PCB (UN5/J403) and the Finisher Controller PCB - DC Controller PCB (UN1) - Relay PCB (UN5) - Finisher Controller PCB [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES - After replacement of the Finisher Controller PCB, refer to "Adjustments> Adjustment when Replacing the Parts" in the Service Manual for the Finisher.
Code: 713-0030-05
Description: Finisher communication error
Causes: An initialization error was detected in communication between the host machine and the finisher.
Remedy: a. STAPLE/BOOKLET FINISHER-Y1 [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN1/J110), the Relay Path Unit and the Finisher Controller PCB - Harnesses connecting the Relay PCB (UN5/J403), the Relay Path Unit and the Finisher Controller PCB - DC Controller PCB (UN1) - Relay PCB (UN5) - Relay Path Unit - Finisher Controller PCB b. INNER FINISHER-H1 [Related parts] - Harness between the DC Controller PCB (UN1/J110) and the Finisher Controller PCB - Harness between the Relay PCB (UN5/J403) and the Finisher Controller PCB - DC Controller PCB (UN1) - Relay PCB (UN5) - Finisher Controller PCB [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES - After replacement of the Finisher Controller PCB, refer to "Adjustments> Adjustment when Replacing the Parts" in the Service Manual for the Finisher.
Code: 719-0001-00
Description: Error in Coin Vendor.
Causes: Error in starting of the CoinVendor - The Coin Vendor, which should have been connected before the power was turned OFF, is not connected when the power is turned ON.
Remedy: Check the connection between charging management equipment and machine, and check that the Cable is not open-circuit. Clear the error while the charging management equipment is connected to operate and when switching to the operation without charging management equipment. (To prevent the misuse by removing the charging management equipment, this error code is displayed.)
Code: 719-0002-00
Description: Error in Coin Vendor.
Causes: Error in IPC when CoinVendor is running. - In the case of disconnection of IPC or an error in which IPC communication failed to be recovered. - When disconnection of the pickup delivery signal is detected. - When illegal connection is detected (short-circuit with Tx and Rx of IPC)
Remedy: Check the connection between charging management equipment and machine, and check that the Cable is not open-circuit. Clear the error while the charging management equipment is connected to operate and when switching to the operation without charging management equipment. (To prevent the misuse by removing the charging management equipment, this error code is displayed.)
Code: 719-0003-00
Description: Error in Coin Vendor.
Causes: - In the case of communication error with the coin vendor while obtaining the unit price at start-up.
Remedy: Check the connection between charging management equipment and machine, and check that the Cable is not open-circuit. Clear the error while the charging management equipment is connected to operate and when switching to the operation without charging management equipment. (To prevent the misuse by removing the charging management equipment, this error code is displayed.)
Code: 719-0004-00
Description: Coin vendor error
Causes: The coin vendor was connected to a model that does not support the coin vendor
Remedy: 1. Disconnect the coin vendor
Code: 719-0031-00
Description: Error in serial communication at the start of the New Card Reader
Causes: Failure in communication with the serial New Card Reader at start-up.
Remedy: - Check if the cable of the serial New Card Reader is disconnected. - Take out the serial New Card Reader. - COPIER > Function > CLEAR > CARD - COPIER > Function > CLEAR > ERR