Code: 199-0002-05

Description: Sequence error
Causes: Software process error (for log collection)
Remedy: [Remedy] Collect debug log and contact the sales company. [Reference] By setting "COPIER (LEVEL2)> OPTION> FNC-SW> SELF-CHK" to "1", it is handled as an error.

Code: 202-0001-04

Description: Reader Scanner Unit HP error
Causes: The Reader Scanner Unit could not detect the home position when starting scanning operation.
Remedy: [Related parts] R1.00 - Harness between the Reader Controller PCB (UN1/J102) and the Scanner Unit HP Sensor (PS2/ J5202) - Harness between the Reader Controller PCB (UN1/J108) and the Scanner Motor (M1/J601) - Scanner Unit HP Sensor (PS2) - Scanner Motor (M1) - Reader Controller PCB (UN1) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES

Code: 202-0002-04

Description: Reader Scanner Unit HP error
Causes: The Reader Scanner Unit could not detect the home position when completing scanning operation.
Remedy: [Related parts] R1.00 - Harness between the Reader Controller PCB (UN1/J102) and the Scanner Unit HP Sensor (PS2/ J5202) - Harness between the Reader Controller PCB (UN1/J108) and the Scanner Motor (M1/J601) - Scanner Unit HP Sensor (PS2) - Scanner Motor (M1) - Reader Controller PCB (UN1) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES

Code: 202-0003-04

Description: Reader Scanner Unit HP error
Causes: An error in the Reader Scanner Unit position was detected when reading of a job was started.
Remedy: [Related parts] R1.00 - Harness between the Reader Controller PCB (UN1/J102) and the Scanner Unit HP Sensor (PS2/ J5202) - Harness between the Reader Controller PCB (UN1/J108) and the Scanner Motor (M1/J601) - Scanner Unit HP Sensor (PS2) - Scanner Motor (M1) - Reader Controller PCB (UN1) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES

Code: 202-0101-04

Description: DADF Glass HP error
Causes: The DADF Glass (for back side) could not detect the home position when starting scanning operation.
Remedy: [Related parts] R1.00 - Harness between the DADF Driver PCB (UN3/J413) and the Glass HP Sensor (SR18/J630) - Harness between the DADF Driver PCB (UN3/J415) and the Glass Shift Motor (M8/J1225) - Glass HP Sensor (SR18) - Glass Shift Motor (M8) - DADF Driver PCB (UN03) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: 202-0102-04

Description: DADF Glass HP error
Causes: The DADF Glass (for back side) could not detect the home position when completing scanning operation.
Remedy: [Related parts] R1.00 - Harness between the DADF Driver PCB (UN3/J413) and the Glass HP Sensor (SR18/J630) - Harness between the DADF Driver PCB (UN3/J415) and the Glass Shift Motor (M8/J1225) - Glass HP Sensor (SR18) - Glass Shift Motor (M8) - DADF Driver PCB (UN03) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: 227-0001-04

Description: Power supply error
Causes: The Reader Controller PCB did not detect 24 V when the main power was turned ON.
Remedy: [Related parts] R1.00 - Harness between the Reader Controller PCB (UN1/J111) and the DADF Driver PCB (UN03/J402) - Harness between the Reader Controller PCB (UN1/J101) and the Relay PCB (UN7/J1808) - Harness between the Relay PCB (UN7/J1802) and the DC Power Supply PCB (24VA) (UN34/ J202) - Harness between the Relay PCB (UN7/J1803) and the DC Power Supply PCB (24VB) (UN35/ J2020) - Harness between the DC Power Supply PCB (24VA/24VB) (UN34/J102 and UN35/J1020) and the AC Driver PCB (UN8/J810 and J813) - Harnesses between the DC Controller PCB (UN2/J1200 and J1224) and the Relay PCB (UN7/ J1817 and J1805) - Reader Controller PCB (UN1) - DADF Driver PCB (UN03) - Relay PCB (UN7) - DC Power Supply PCB (24VA) (UN34) - DC Power Supply PCB (24VB) (UN35) - AC Driver PCB (UN8) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - When an error is detected, conduction of 24 V is stopped. At power check, check if 24 V is conducted or rated voltage is output by repeating power cycling of the machine. - Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES - Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: 227-0101-04

Description: Power supply error
Causes: The DADF Driver PCB did not detect 24 V when the main power was turned ON.
Remedy: [Related parts] R1.00 - Harness between the Reader Controller PCB (UN1/J111) and the DADF Driver PCB (UN3/J402) - Harness between the Reader Controller PCB (UN1/J101) and the Relay PCB (UN7/J1808) - Harness between the Relay PCB (UN7/J1802) and the DC Power Supply PCB (24VA) (UN34/ J202) - Harness between the Relay PCB (UN7/J1803) and the DC Power Supply PCB (24VB) (UN35/ J2020) - Harness between the DC Power Supply PCB (24VA/24VB) (UN34/J102 and UN35/J1020) and the AC Driver PCB (UN8/J810 and J813) - Harnesses between the DC Controller PCB (UN2/J1200 and J1224) and the Relay PCB (UN7/ J1817 and J1805) - Reader Controller PCB (UN1) - DADF Driver PCB (UN3) - Relay PCB (UN7) - DC Power Supply PCB (24VA) (UN34) - DC Power Supply PCB (24VB) (UN35) - AC Driver PCB (UN8) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - When an error is detected, conduction of 24 V is stopped. At power check, check if 24 V is conducted or rated voltage is output by repeating power cycling of the machine. - Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES - Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES