Description: Error in the gripper motor(Finisher-A1). The gripper does not come off the position sensor when the gripper motor has been driven for 3sec.
Remedy: 1. The connector of the gripper position sensor (S115) or the gripper motor (M117) are disconnected. 2. The wiring of the gripper position sensor (S115) or the gripper motor (M117) are faulty. 3. The gripper position sensor (S115) is faulty. 4. The gripper motor (M117) is faulty. 5. The finisher controller PCB is faulty
Code: E514-8006
Description: Error in the gripper motor(Finisher-A1). The gripper position sensor does not detect the gripper when the gripper motor has been driven for 3sec.
Remedy: 1. The connector of the gripper position sensor (S115) or the gripper motor (M117) are disconnected. 2. The wiring of the gripper position sensor (S115) or the gripper motor (M117) are faulty. 3. The gripper position sensor (S115) is faulty. 4. The gripper motor (M117) is faulty. 5. The finisher controller PCB is faulty
Code: E518-8001
Description: Error in folding feed motor lock(Document Insertion / Folding Unit/Paper Folding Unit). The fold transport motor (M5)/(M11) lock signal has been detected for more than the specified time
Remedy: 1. Connector of Folding feed motor (M5)/(M11) is disconnectedFolding feed motor. 2. Folding feed motor (M11) is faulty.(M5)/(M11)
Code: E519-0002
Description: Gear change home position error(Finisher-B1). The gear change home position sensor does not turn ON when the gear change motor has been driven for 387 pulses.
Remedy: 1) The gear change home position sensor (PI117) is faulty. 2) The wiring between the finisher controller PCB and gear change motor is faulty. 3) The gear change mechanism is faulty. 4) The gear change motor (M110) is faulty. 5) The finisher controller PCB
Code: E519-8001
Description: Gear change home position error(Finisher-B1). The gear change home position sensor does not turn OFF when the gear change motor has been driven for 387 pulses.
Remedy: 1) The gear change home position sensor (PI117) is faulty. 2) The wiring between the finisher controller PCB and gear change motor is faulty. 3) The gear change mechanism is faulty. 4) The gear change motor (M110) is faulty. 5) The finisher controller PCB
Code: E530-8000
Description: Error in the front or rear alignment motor. The front or rear alignment motor operate abnormally during initialization.
Remedy: 1. The connector of the front/rear alignment HP sensor (S108/S109) or the front/rear alignment motor (M108/ M109) are disconnected. 2. The wiring of the front/rear alignment HP sensor (S108/ S109) or the front/rear alignment motor (M108/M109) are faulty. 3. The front/rear alignment HP sensor (S108/S109) is faulty. 4. The front/rear alignment motor (M108/M109) is faulty. 5. The finisher controller PCB is faulty.
Code: E530-8001
Description: A. Error in the front alignment motor(Finisher-A1) B. Front aligning plate home position error(Finisher-B1). A. The front alignment plate does not come off the front alignment HP sensor when the front alignment motor has been driven for 4sec. B. The aligning plate does not leave the aligningplate front home position sensor when thealignment plate front motor has been driven for 4 seconds.
Remedy: A: 1. The connector of the front alignment HP sensor (S108) or the front alignment motor (M108) are disconnected. 2. The wiring of the front alignment HP sensor (S108) or the front alignment motor (M108) are faulty. 3. The front alignment HP sensor (S108) is faulty. 4. The front alignment motor (M108) is faulty. 5. The finisher controller PCB is faulty. B: 1) The front aligning plate home position sensor (PI106) is faulty. 2) The wiring between the finisher controller PCB and front aligning plate motor is faulty. 3) The front aligning plate is faulty. 4) The front aligning plate motor (M103) is faulty. 5) The finisher controller PCB is faulty.
Code: E530-8002
Description: A.Error in the front alignment motor(Finisher-A1) B.Front aligning plate home position error(Finisher-B1). A. The front alignment HP sensor does not detect the front alignment plate when the front alignment motor has been driven for 4sec. B. The aligning plate does not return to aligning plate front home position sensor when the alignment plate front motor has been driven for 4 seconds.
Remedy: A: 1. The connector of the front alignment HP sensor (S108) or the front alignment motor (M108) are disconnected. 2. The wiring of the front alignment HP sensor (S108) or the front alignment motor (M108) are faulty. 3. The front alignment HP sensor (S108) is faulty. 4. The front alignment motor (M108) is faulty. 5. The finisher controller PCB is faulty. B: 1) The front aligning plate home position sensor (PI106) is faulty. 2) The wiring between the finisher controller PCB and front aligning plate motor is faulty. 3) The front aligning plate is faulty. 4) The front aligning plate motor (M103) is faulty. 5) The finisher controller PCB is faulty.