Description: Front Alignment Motor (M4) error
At initialization of the Front Alignment Plate, the Front Alignment Plate failed to move from the Front Alignment Plate HP Sensor (S4) although the Front Alignment Motor (M4) was driven for 10 mm.
Remedy: 1. Check the connector connection of the Front Alignment Plate HP Sensor (S4) or the Front Alignment Motor (M4). 2. Check for open circuit of the Harness of the Front Alignment Plate HP Sensor (S4) or the Front Alignment Motor (M4). 3. Replace the Front Alignment Plate HP Sensor (S4). 4. Replace the Front Alignment Motor (M4). 5. Replace the Finisher Controller PCB.
Description: Front Alignment Motor (M4) error
At initialization of the Front Alignment Plate, the Front Alignment Plate failed to be detected by the Front Alignment Plate HP Sensor (S4) although the Front Alignment Motor (M4) was driven for 0.78 seconds.
Remedy: 1. Check the connector connection of the Front Alignment Plate HP Sensor (S4) or the Front Alignment Motor (M4). 2. Check for open circuit of the Harness of the Front Alignment Plate HP Sensor (S4) or the Front Alignment Motor (M4). 3. Replace the Front Alignment Plate HP Sensor (S4). 4. Replace the Front Alignment Motor (M4). 5. Replace the Finisher Controller PCB.
Description: Staple Motor (M9) error
The Stapler failed to move from the Staple HP Sensor (S11) within the staple execution time (0.45sec).
Remedy: 1. Check the connector connection of the Staple Unit. 2. Check for open circuit of the Harness of the Staple Unit. 3. Replace the Staple Unit. 4. Replace the Finisher Controller PCB.
Description: Staple Motor (M9) error
After execution of staple operation, the motor was operated in the positive direction, but the Staple Unit could not be detected by the Staple HP Sensor (S11) within 0.46 seconds. Then, the motor was rotated in the negative direction, but the Staple Unit could not be detected by the Staple HP Sensor (S11) within 0.46sec.
Remedy: 1. Check the connector connection of the Staple Unit. 2. Disconnect the Harness of the Staple Unit. 3. Replace the Staple Unit. 4. Replace the Finisher Controller PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.