Code: E225-0000

Description: The light intensity of the CCD is faulty.
The light intensity of the CCD during shading is under the specified level.
Remedy: 1.Disconnect and then connect the flexible cable. 2.Replace the flexible cable. 3.Replace the CCD Unit. 4.Replace the Relay PCB (PCB2). 5.Replace the Main Controller PCB (PCB1).

Code: E227-0000

Description: The reader unit power supply (24V) is faulty.
1.At time of power-on, the 24V port is off.
2.At the start of a job, the 24V port is off.
3.At the end of a job, the 24V port is off.
4.When a load is being driven, the 24V port is off.
Remedy: 1.Disconnect and then connect the power supply harness connector. 2.Replace the Power Supply PCB (PCB3).

Code: E240-0000

Description: Error in controller communication
The serial communication error such as parity error or overrun error is constantly detected.
Remedy: 1.Check the Connectors. 2.Replace the DC Controller PCB (PCB4).

Code: E240-0001

Description: Error in controller communication
The serial communication error such as parity error or overrun error is detected while printing.
Remedy: 1.Check the Connectors. 2.Replace the DC Controller PCB (PCB4).

Code: E248-0000

Description: EEPROM error
1.An error has occurred at power-on.
2.An error has occurred during write operation.
3.An error has occurred during read operation following write operation.
Remedy: 1.Disconnect and then connect the flexible cable(Relay PCB (PCB2)-Main Controller PCB (PCB1) 50pin). 2.Disconnect and then connect the flexible cable(CCD unit- Relay PCB (PCB2)). 3.Disconnect and then connect the power supply harness connector. 4.Replace the flexible cable. 5.Replace the CCD Unit. 6.Replace the Relay PCB (PCB2). 7.Replace the Power Supply PCB (PCB3). 8.Replace the Main Controller PCB (PCB1).

Code: E261-0000

Description: Error in Zero Cross
Zero Cross failed to be detected for 500ms or more while the relay was ON.
* The same condition is detected after the error retry is performed.
Remedy: 1.Check the Connectors. 2.Replace the DC Controller PCB (PCB4).

Code: E280-0000

Description: Reading unit communication error
Reading error after writing.
Remedy: 1.Disconnect and then connect the flexible cable(Relay PCB (PCB2)-Main Controller PCB (PCB1) 50pin). 2.Disconnect and then connect the flexible cable(Relay PCB (PCB2)-Main Controller PCB (PCB1) 64pin). 3.Disconnect and then connect the flexible cable(CCD unit- Relay PCB (PCB2)). 4.Replace the flexible cable. 5.Replace the Relay PCB (PCB2). 6.Replace the Main Controller PCB (PCB1).

Code: E413-0000

Description: Release Motor (M2) error
The sensing level of the release motor HP sensor (SR11) does not change within a specified period when the release motor (M2) is driven.
Remedy: 1.Replace the Release Motor HP Sensor (SR11). 2.Replace the Release Motor (M2). 3.Replace the ADF Driver PCB.