Description: The temperature of the fixing assembly is abnormally high.
While startup control is under way, the reading of the main thermistor is less than 30 deg C continuously for 200 msec or more 1 sec after the start of power supply. While startup control is under way, the reading of the main thermistor is less than 70 deg C continuously for 200 msec or more 2 sec after the start of power supply. While startup control is under way, the reading of the main thermistor is less than 120 deg C continuously for 200 msec 6 sec after the start of power supply. The startup control does not end 30 sec after the start of power supply.
Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor. Replace the DC controller PCB.
Code: E001-0000
Description: The temperature of the fixing assembly is abnormally high.
The reading of the main thermistor is 250 deg C or more continuously for 200 msec.
Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor. Replace the DC controller PCB.
Code: E001-0001
Description: The temperature of the fixing assembly is abnormally high.
The hardware circuit detects overheating of the main or sub thermistor for 200 msec
Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR. Replace the DC controller PCB.
Code: E001-0002
Description: The temperature of the fixing assembly is abnormally high.
The reading of the sub thermistor is 295 deg C or more continuously for 200 msec.
Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR. Replace the sub thermistor. Replace the DC controller PCB.
Code: E002-0000
Description: The rise in temperature of the fixing assembly is faulty.
While startup control is under way, the reading of the main thermistor is less than 115 deg C continuously for 400 msec 1.3 sec after it has indicated 100 deg C. While startup control is under way, the reading of the main thermistor is less than 150 deg C continuously for 400 msec 1.3 sec after it has indicated 140 deg C.
Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor. Replace the DC controller PCB.
Code: E003-0000
Description: The fixing temperature is too low after a standby state.
While regular temperature control is under way, the reading of the main thermistor is less than 140 deg C continuously for 400 msec or more
Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor. Replace the DC controller PCB.
Code: E004-0000
Description: Failure in main/sub thermistor
When disconnection is detected with connector of the main/sub thermistor for 30 sec continuously while DC controller is working.
Remedy: Clear the error in Service Mode: COPIER > FUNCTION > CLEAR > ERR. Replace the main thermistor (film unit). Replace DC controller PCB.
Code: E007-0000
Description: The rotation of the fixing film is faulty.
While the fixing motor is rotating, the marker signal is not detected for 6 sec with the reading of the main thermistor indicating 100 deg C or more.
Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR. Replace the main thermistor. Replace the DC controller PCB.