Description: The scanner motor is faulty.
The scanner motor speed lock signal does not indicate a locked state a specific period of time after the scanner motor has been started.
Remedy: Replace the laser unit. Replace the DC controller PCB. Check the wiring.
Description: The scanner motor is faulty.
The speed lock signal indicates a deviation 10 times in sequence at intervals of 10 msec after the signal has indicated a locked state.
Remedy: Replace the laser unit. Replace the DC controller PCB. Check the wiring.
Description: With the image clock switched over, the scanner motor speed lock signal does not indicate a locked state 6.5 sec after a switchover is made from low to normal speed or 8 sec after a switchover is made from normal to low speed.
Remedy: Replace the laser unit. Replace the DC controller PCB. Check the wiring.
Description: There is an error in the communication with the high-voltage power supply.
The data transmission/reception does not end normally 500 msec after the most recent transmission/reception of data ended normally.
Remedy: Replace the high-voltage power supply. Replace the DC controller PCB.