Description: The heater fails to heat. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
After power-on, the reading of the main thermistor does not increase to 70 deg C or higher within 20 sec.
Remedy: - Replace the main/shutter thermistor. - Replace the DC controller PCB.
Description: The heater fails to heat. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The power has been turned off and then on without resetting the error.
Remedy: - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
There is an error or an open circuit in the main thermistor, shutter thermistor, or sub thermistor.
Remedy: - Check the connector of each thermistor for any fault in connection and wiring. - Replace the thermistor in question. - Replace the DC controller PCB.
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading of the main thermistor, shutter thermistor, or sub thermistor is 230 deg C or higher for 2 sec.
Remedy: - Replace the thermistor in question. - Replace the DC controller PCB.
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading is not 150 deg C or higher or 210 deg C or lower within 30 sec.
Remedy: -Cheak the connecting of the main/ sub/ shutter thermistors. -Check the mounting of the main/ sub/ shutter thermistors. -Exchange the main/ sub/ shutter thermistors. -Exchange the DC controller PCB.
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The power has been turned off and then back on without resetting the error.
Remedy: - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading of the main thermistor is not 100 deg C 12 sec after it has exceeded 70 deg C.
Remedy: - Check the connector of the main/shutter thermistor for any fault in connection and wiring. - Check the main/shutter thermistor for mounting condition. - Replace the main/shutter thermistor. - Replace the fixing heater unit. - Replace the DC controller PCB.
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading of the main thermistor is not 150 deg C 15 sec after it has exceeded 100 deg C.
Remedy: - Check the connector of the main/shutter thermistor for any fault in connection and wiring. - Check the main/shutter thermistor for mounting condition. - Replace the main/shutter thermistor. - Replace the fixing heater unit. - Replace the DC controller PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.