Description: When the LENS HOME POSITION signal (LHP) is not generated within 4.8 seconds after the power switch or door switch goes ON. When the LENS HOME POSITION signal (LHP) is generated for 2 seconds or more.
Code: E243
Description: When an abnormally in communication occurs between the microprocessors on the DC controller PCB and those on the control panel PCB.
Code: E400
Description: When an abnormality in communication occurs between the DC controller PCB detect RDF controller PCB.
Code: E401
Description: When a flag mounted on the pick-up roller HOME position sensor (S3), it indicates that M1 is turning. S3 should go ON and OFF two or more times in one second.
Code: E402
Description: The number of pulses in a 200 ms period is too low.
Code: E403
Description: When the number of feed motor clock pulses in a 200 ms period is less than the correct value.
Code: E411
Description: When the sensor output is greater than 2.3V when there is paper.
Code: E500
Description: When an abnormality in communication occurs between the DC controller PCB of sorter detect main controller PCB.