Causes: ILS control error has occurred. • Cartridge Holder Board failure • Main Board failure
Remedy: 1. Replace the Cartridge Holder. (Check both right/left ones respectively.) 2. Replace the Main Board.
Code: 1FB9
Description: CSIC error (1)
Causes: CSIC control error has occurred. • Main Board failure
Remedy: Replace the Main Board.
Code: 1FBE
Description: CSIC error (2)
Causes: CSIC control error has occurred. • Cartridge Holder Board failure • Main Board failure
Remedy: 1. Replace the Cartridge Holder. (Check both right/left ones respectively.) 2. Replace the Main Board.
Code: 1FBF
Description: CSIC error (3)
Causes: CSIC control error has occurred. • Cartridge Holder Board failure • Main Board failure
Remedy: 1. Replace the Cartridge Holder. (Check both right/left ones respectively.) 2. Replace the Main Board.
Code: 1FC0
Description: CSIC error (4)
Causes: Communication failure between the Cartridge Holder and Main Board. • Connection failure of the FFC. • Cartridge Holder Board failure • Main Board failure
Remedy: 1. Replace the FFC between the Cartridge Holder and Main Board. (Check both right/left ones respectively.) 2. Replace the Cartridge Holder. (Check both right/left ones respectively.) 3. Replace the Main Board.
Code: 1FC1
Description: CSIC error (5)
Causes: CSIC control error has occurred. • Cartridge Holder Board failure • Main Board failure
Remedy: 1. Replace the Cartridge Holder. (Check both right/left ones respectively.) 2. Replace the Main Board.
Code: 1FC2
Description: CSIC error (6)
Causes: CSIC control error has occurred. • Cartridge Holder Board failure • Main Board failure
Remedy: 1. Replace the Cartridge Holder. (Check both right/left ones respectively.) 2. Replace the Main Board.
Code: 1FC3
Description: CSIC error (7)
Causes: CSIC control error has occurred. • Main Board failure