Description: Motor startup error
CMY drum motor (M2) start up error
Remedy: 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
Description: Motor rotational error
CMY drum motor (M2) rotation error
Remedy: 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
Description: Motor abnormal rotation
CMY developer motor (M3) abnormal start up error
Remedy: 1. Use the developer motor (M3) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the developer motor assembly. 2. If the product has been serviced, check the connector (J514) on the developer motor and the connector (J81) on the DC controller PCA.
Description: Developer motor failure
CMY developer motor (M3) failure error
Remedy: 1. Use the developer motor (M3) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the developer motor assembly. 2. If the product has been serviced, check the connector (J514) on the developer motor and the connector (J81) on the DC controller PCA.
Description: Motor startup error
CMY drum motor (M2) start up error
Remedy: 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
Description: Motor rotational error
CMY drum motor (M2) rotation error
Remedy: 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
Description: Motor abnormal rotation
CMY developer motor (M3) abnormal start up error
Remedy: 1. Use the developer motor (M3) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the developer motor assembly. 2. If the product has been serviced, check the connector (J514) on the developer motor and the connector (J81) on the DC controller PCA.
Description: Developer motor failure
CMY developer motor (M3) failure error
Remedy: 1. Use the developer motor (M3) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the developer motor assembly. 2. If the product has been serviced, check the connector (J514) on the developer motor and the connector (J81) on the DC controller PCA.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.