Description: Printing error
Fuser motor (M4) start up error or fuser motor (M4) rotational error
Remedy: 1. Use the fuser motor (M4) drive test in the component test to verify that the fuser motor is properly functioning. If it is not, replace the fuser motor assembly. 2. If the product has been serviced, check the connector (J516) on the fuser motor and the connector (J81) on the DC controller PCA.
Code: 59.00.90
Display: 59.00.YY Error
Description: Printing error
ITB motor (M1) start up error or ITB motor (M1) abnormal rotational error
Remedy: 1. Use the ITB motor (M1) drive test in the component test to verify that the ITB motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
Code: 59.00.A0
Display: 59.00.YY Error
Description: Printing error
ITB motor (M1) start up error or ITB motor (M1) abnormal rotational error
Remedy: 1. Use the ITB motor (M1) drive test in the component test to verify that the ITB motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
Code: 59.00.C0
Display: 59.00.YY Error
Description: Printing error
Developer alienation motor (M6) error
Remedy: 1. Use the developer engagement and disengagement drive test in the component test to verify that the disengagement mechanism is properly functioning. If it is not, replace the ITB motor assembly. 2. Use the sensor test in the Manual sensor test to verify that the developer disengagement sensor (PS11) is properly functioning. If it is not, replace the main drive assembly. 3. If the product has been serviced, check the connector (J518) on the developer disengagement motor, the connector (J1005) on the driver PCA and the connector (J91) on the DC controller PCA.
Remedy: 1. Make sure that the ITB is correctly installed. 2. Use the T1 roller alienation switch (SW5) test in the Manual sensor test to verify that the switch is properly functioning. If it is not, replace the main drive assembly. 3. Use the T1 roller engagement and disengagement drive test in the component test to verify that the T1 roller disengagement mechanism is properly functioning. If it is not, replace the fuser drive assembly. 4. If the product has been serviced, check the connector (J181) on the DC controller PCA.
Code: 59.05.50
Display: 59.0X.50 Error
Description: Motor startup error
Black image drum start up error (ITB motor; M1)
Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
Code: 59.05.70
Display: 59.0X.70 Error
Description: Motor abnormal rotation
Black developer motor abnormal start up error (ITB motor; M1)
Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
Code: 59.05.80
Display: 59.0X.80 Error
Description: Developer motor failure
Black developer motor failure error (ITB motor; M1)
Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.