Description: Motor startup error
CMY drum motor (M2) start up error
Remedy: 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
Code: 59.08.60
Display: 59.0X.60 Error
Description: Motor rotational error
CMY drum motor (M2) rotation error
Remedy: 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
Code: 59.08.70
Display: 59.0X.70 Error
Description: Motor abnormal rotation
CMY developer motor (M3) abnormal start up error
Remedy: 1. Use the developer motor (M3) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the developer motor assembly. 2. If the product has been serviced, check the connector (J514) on the developer motor and the connector (J81) on the DC controller PCA.
Code: 59.08.80
Display: 59.0X.80 Error
Description: Developer motor failure
CMY developer motor (M3) failure error
Remedy: 1. Use the developer motor (M3) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the developer motor assembly. 2. If the product has been serviced, check the connector (J514) on the developer motor and the connector (J81) on the DC controller PCA.
Code: 60.00.02
Display: 60.00.0Y Tray <Y> lifting error
Description: Tray lift motors error
Media input Tray 2 lift-up motor (M9) failure
Remedy: 1. Use the Tray 2 paper surface sensor (PS4) test in the Tray/Bin manual sensor test to verify that the sensor is properly functioning. If it is not, replace the lifter drive assembly. 2. Open and close Tray 2 and listen at the back of the product for the sound of the lifer motor (M9) operating. If it does not operate, replace the lifter drive assembly. 3. If the product has been serviced, check the intermediate connector (J742) and the connector (J151) on the DC controller PCA. 4. If the error persists, replace the cassette tray.
Code: 60.00.03
Display: 60.00.0Y Tray <Y> lifting error
Description: Tray lift motors error
Media input Tray 3 lift-up motor (M2) failure or media input Tray 4 lift-up motor (M2) failure
Remedy: 1. Use the Tray 3 paper surface sensor (SR2) or Tray 4 paper surface sensor (SR2) test in the Tray/ Bin manual sensor test to verify that the sensor is properly functioning. If it is not, replace the lifter drive assembly. NOTE: Both the Tray 3 and Tray 4 paper surface sensors are designated as SR2. The first one listed in the Tray/Bin manual test is Tray 3, the second one listed is for Tray 4. 2. Open and close Tray 3 or Tray 4 and listen at the back of the product for the sound of the lifer motor (M2) operating. If it does not operate, replace the lifter drive assembly. NOTE: Both the Tray 3 and Tray 4 lifter motors are designated as M2. Listen for the appropriate motor to operate. 3. If the product has been serviced, check the connector (J2003) on the paper feeder controller PCA, the intermediate connector (J702) and the connector (J2006) on the paper feeder controller PCA. TIP: Check the connector (J2006) on the paper feeder controller PCA associated with the tray. 4. If the error persists, replace the cassette tray.
Code: 60.00.05
Display: 60.00.0Y Tray <Y> lifting error
Description: Tray lift motors error
Media input Tray 5 lift-up motor (M82) failure or media input Tray 6 lift-up motor (M92) failure
Remedy: 1. Use the Tray 5 paper surface sensor (SR82) or Tray 6 paper surface sensor (SR92) test in the Tray/Bin manual sensor test to verify that the sensor is properly functioning. If it is not, replace the lifter drive assembly. 2. Open and close Tray 5 or Tray 6 and listen at the back of the product for the sound of the lifer motor (M82 or M92) operating. If it does not operate, replace the lifter drive assembly. 3. If the product has been serviced, check the connector (J2003) on the paper feeder controller PCA, the intermediate connector (J702) and the connector (J2006) on the paper feeder controller PCA. TIP: Check the connector (J2006) on the paper feeder controller PCA associated with the tray. 4. If the error persists, replace the cassette tray.
Code: 60.00.06
Display: 60.00.0Y Tray <Y> lifting error
Description: Tray lift motors error
Media input Tray 5 lift-up motor (M82) failure or media input Tray 6 lift-up motor (M92) failure
Remedy: 1. Use the Tray 5 paper surface sensor (SR82) or Tray 6 paper surface sensor (SR92) test in the Tray/Bin manual sensor test to verify that the sensor is properly functioning. If it is not, replace the lifter drive assembly. 2. Open and close Tray 5 or Tray 6 and listen at the back of the product for the sound of the lifer motor (M82 or M92) operating. If it does not operate, replace the lifter drive assembly. 3. If the product has been serviced, check the connector (J2003) on the paper feeder controller PCA, the intermediate connector (J702) and the connector (J2006) on the paper feeder controller PCA. TIP: Check the connector (J2006) on the paper feeder controller PCA associated with the tray. 4. If the error persists, replace the cassette tray.