Description: The Printer has detected a leak in the Tubes System before the life of the System.
Remedy: • Check for ink in the Ink Leak Detector and, if present, replace the complete Tubes System • The Ink Leak Detector could have been trigggered due to condensation in the Printer. Power OFF the Printer and allow the Printer to dry for 15 minutes. Power ON and check if the System Error Code has disappeared. • Replace the ISS PCA WARNING Only replace one component at a time and check if the error has gone before replacing another component. Using this procedure you will be able to determine exactly which component failed.
Description: The Printer has detected a leak in the Tubes System after the life of the System.
Remedy: • Check for ink in the Ink Leak Detector and, if present, replace the complete Tubes System • The Ink Leak Detector could have been trigggered due to condensation in the Printer. Power OFF the Printer and allow the Printer to dry for 15 minutes. Power ON and check if the System Error Code has disappeared. • Replace the ISS PCA WARNING Only replace one component at a time and check if the error has gone before replacing another component. Using this procedure you will be able to determine exactly which component failed.
Remedy: • Check that the cable from the Ink Supply Station (ISS) PCA to the Ink Supply Station is correctly connected. • Check that the Air Pressurization System Sensor Cable is correctly connected and is NOT damaged. • Check all the tubes of the APS and make sure they are NOT pinched or damaged. • Faulty APS. Replace the APS • If the error code continues, replace the Main PCA WARNING Only replace one component at a time and check if the error has gone before replacing another component. Using this procedure you will be able to determine exactly which component failed.
Remedy: • Check that the cable from the Ink Supply Station (ISS) PCA to the Ink Supply Station is correctly connected. • Faulty APS. Replace the APS • If the error code continues, replace the Main PCA WARNING Only replace one component at a time and check if the error has gone before replacing another component. Using this procedure you will be able to determine exactly which component failed.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.