Remedy: 1. Make sure that the ITB is correctly installed. 2. Use the T1 roller alienation switch (SW5) test in the Manual sensor test to verify that the switch is properly functioning. If it is not, replace the main drive assembly. 3. Use the T1 roller engagement and disengagement drive test in the component test to verify that the T1 roller disengagement mechanism is properly functioning. If it is not, replace the fuser drive assembly. 4. If the product has been serviced, check the connector (J181) on the DC controller PCA.
Code: 59.05.50
Display: 59.0X.50 Error To continue turn off then on
Description: Motor startup error X= 5 black, X = 6 cyan, X = 7 magenta, X = 8 yellow
Black image drum start up error (ITB motor; M1)
Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
Code: 59.05.70
Display: 59.0X.70 Error To continue turn off then on
Description: Motor abnormal rotation
Black developer motor abnormal start up error (ITB motor; M1)
Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
Code: 59.05.80
Display: 59.0X.80 Error To continue turn off then on
Description: Developer motor failure
Black developer motor failure error (ITB motor; M1)
Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
Code: 59.06.50
Display: 59.0X.50 Error To continue turn off then on
Description: Motor startup error X= 5 black, X = 6 cyan, X = 7 magenta, X = 8 yellow
CMY drum motor (M2) start up error
Remedy: 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
Code: 59.06.60
Display: 59.0X.60 Error To continue turn off then on
Description: Motor rotational error X= 5 black, X = 6 cyan, X = 7 magenta, X = 8 yellow
Remedy: CMY drum motor (M2) rotation error 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
Code: 59.06.70
Display: 59.0X.70 Error To continue turn off then on
Description: Motor abnormal rotation
CMY developer motor (M3) abnormal start up error
Remedy: 1. Use the developer motor (M3) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the developer motor assembly. 2. If the product has been serviced, check the connector (J514) on the developer motor and the connector (J81) on the DC controller PCA.
Code: 59.06.80
Display: 59.0X.80 Error To continue turn off then on
Description: Developer motor failure
CMY developer motor (M3) failure error
Remedy: 1. Use the developer motor (M3) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the developer motor assembly. 2. If the product has been serviced, check the connector (J514) on the developer motor and the connector (J81) on the DC controller PCA.