Các lỗi thường gặp

Code :
  • Code: 30.1.18
  • Display: 30.1.18 Scan failure
  • Description: The product has experienced an ASIC error.
  • Remedy: - Turn the product off, and then disconnect the power cord. - Connect the power cord, and then turn the product on. - Check connections to the SCB. - Check connections to the intermediate PCA, the analog processor PCA, and the CCD driver PCA. - Replace the SCB. - Replace the flatbed optical assembly.
  • Code: 30.1.19
  • Display: 30.1.19 Scan failure
  • Description: Lamp error
  • Remedy: - Turn the product off, and then on. - Check to see that the scanner lamp illuminates while the product is turned on. - Check the connections to the SCB. - Replace the SCB. - Replace the flatbed optical assembly.
  • Code: 30.1.22
  • Display: 30.1.22 Scan failure
  • Description: CP processing error.
  • Remedy: - Turn the product off, and then disconnect the power cord. - Connect the power cord, and then turn the product on.
  • Code: 30.1.25
  • Display: 30.1.25 Scan failure
  • Description: Copy processor board error.
  • Remedy: - Turn the product off, and then disconnect the power cord. - Connect the power cord, and then turn the product on. - Check the copy processor LED. - Check connections to the copy processor board. - Check the scan engine cable connection. - Replace the copy processor board.
  • Code: 30.1.29
  • Display: 30.1.29 ADF output bin full
  • Description: The ADF output bin is full.
  • Remedy: - Empty the ADF output bin. - Check the connection to the ADF output bin full sensor. - Check the connection to the scanner controller board. - Replace the ADF output bin full sensor. - Replace the scanner controller board.
  • Code: 30.1.30
  • Display: 30.1.30 Scan failure
  • Description: DC FIFO overrun.
  • Remedy: - Turn the product off, and then on. - Check the connection to the scanner controller board. - Replace the scanner controller board. - Turn the product off, and then on.
  • Code: 30.1.31
  • Display: 30.1.31 Scan failure
  • Description: SSI FIFO overrun.
  • Remedy: - Turn the product off, and then on. - Check the connection to the scanner controller board. - Check the scan engine cable connection. - Replace the copy processor board.
  • Code: 30.1.32
  • Display: 30.1.32 Scan failure
  • Description: Corrupt scan.
  • Remedy: - Restart the scan job. - Turn the product off, and then on. - Check the scan engine cable connection.