Các lỗi thường gặp

Code :
  • Code: 43.4:10
  • Description: VacuumFan Low Performance: Vacuum Fan is not working at the desired performance., SVS side
  • Causes: Vacuum fan failure.
  • Remedy: Call agent: • Switch the power off at the rear of the printer, wait briefly, then switch it back on again. Service engineer: • Replace the Vacuum Fan SVS side.
  • Code: 43:11
  • Description: Vacuum fan not connected
  • Causes: Vacuum fan not connected.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the cable connections between the Mini Interconnect PCA and Eola SVS side. 2. Replace Eolas. 3. Replace the Mini Interconnect PCA.
  • Code: 44:10
  • Description: Aerosol Fan Fault
  • Causes: Aerosol Fan damaged Interconnect PCA damaged (very low probability) PrintMech PCA (very low probability).
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check that the Aerosol Fan cable is correctly connected to the Interconnect PCA. 2. Check that the cables going from the Interconnect PCA to the PrintMech PCA are correctly connected. 3. Replace the Aerosol Fan. See Aerosol fan assembly. 4. If the previous action did not work then, replace the PrintMech PCA. See PrintMech PCA.
  • Code: 45:03
  • Description: Rewinder servo shutdown
  • Causes: Rewinder motor disconected. Rewinder motror damaged. Rewinder motor cable damaged. Interconnect PCA damaged (very low probability). PrintMech PCA damaged (very low probability).
  • Remedy: Call agent: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. pen the Window and check for any visible obstacles restricting the movement of the Drive Roller. If there is a wrinkled mass of substrate inside the substrate path, lift the Pinch Wheels and clear the obstruction. Service engineer: 1. Revise the Rewinder motor cable connections to Interconnect PCA. 2. Replace the Rewinder Motor. See Rewinder. 3. If the previous action did not work then, replace the PrintMech PCA. 4. If the previous action did not work then, replace the Interconnect PCA.
  • Code: 46:03
  • Description: Primer servo shutdown
  • Causes: Primer failure.
  • Remedy: Call agent: 1. Check that the Primer Arm is not damaged and there are no obstacles in its way. 2. Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power cord and turn on the printer. Service engineer: • Replace the Primer Assembly. See Primer assembly.
  • Code: 46:10
  • Description: Primer fault
  • Causes: Primer fault.
  • Remedy: Call agent: 1. Check that the Primer Arm is not damaged and there are no obstacles in its way. 2. Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power cord and turn on the printer. Service engineer: • Replace the Primer Assembly. See Primer assembly.
  • Code: 46:13
  • Description: Primer test distance failed
  • Causes: Primer encoder is damaged. Primer cable is damaged. Interconnect PCA is damaged (very low probability). PrintMech PCA is damaged (very low probability).
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check that the Primer Arm is not damaged and there are no obstacles in its way. 2. Check that Primer cable is not damaged and correctly connected to the Interconnect PCA. 3. Replace the Primer Assembly. See Primer assembly. 4. Replace the PrintMech PCA. See PrintMech PCA. 5. Replace the Interconnect PCA. See Interconnect PCA.
  • Code: 50.1:10
  • Description: OMAS: error with the media advance sensor component or with the cable between sensor and controller
  • Causes: OMAS communication failure.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check that the OMAS Controller to OMAS Sensor cable is not damaged and is correctly connected to the OMAS Controller Card and the OMAS Module. 2. Replace the OMAS Module. See OMAS. 3. Replace the OMAS controller PCA. See OMAS controller PCA.